| 2001-12-28 00:00:00 | CHECKLIST: |
| | 1-AFTER ORIGINAL DRAWINGS ARE REVISED, |
| | PLEASE BRING THEM TO THE COUNTY TO |
| | PAY IMPACT FEES. BRING PAID RECEIPT. |
| | 2-NEED TO RECORD NOTICE OF COMMENCEMENT. |
| | 3-PROVIDE SOIL TEST REPORT WITH INFO. |
| | REQUIRED ON SECTION 1804.2.7 OF CITY |
| | AMENDMENTS TO SBC 1997. |
| | 4-ARCHITECT TO FILL OUT THE DESIGN |
| | CERTIFICATION FOR BUILDING CODE |
| | COMPLIANCE FORM. ATTACHED. |
| | 5-SPECIFY SAFETY GLASS WHERE REQUIRED. |
| | SEE PLANS AND SECTION 2405.2 SBC 1997. |
| | 6-REVISE ENERGY CALCULATIONS: |
| | A)REVISE UNDER ATTIC AREA. SEE SECTION |
| | 604.1.A.1 FLORIDA ENERGY EFFICIENCY |
| | CODE FOR BUILDING CONSTRUCTION, 1997. |
| | B)REVISE # OF BEDROOMS. SEE PLANS AND |
| | BEDRM DEFINITION ON FL. ENERGY CODE. |
| | C)COMPLETE INFORMATION ON TOP OF FORM. |
| | D)OWNER/AGENT TO SIGN AND DATE THE |
| | ENERGY CALCULATIONS. |
| | |
| | 7-PROVIDE PLANS FOR OPTIONAL BATHROOM |
| | AT BEDROOM #4. |
| | 8-SPECIFY SIZE OF ATTIC ACCESS. SECTION |
| | 2309.6 SBC 1997. |
| | 9-BEDROOM #5 WINDOWS DON'T COMPLY WITH |
| | EGRESS REQUIREMENTS OF SECTION 1005.4 |
| | SBC 1997. 24SH WINDOW DON'T PROVIDE |
| | THE MIN. CLEAR HT OPENING REQUIRED. |
| | 10-PROVIDE COMPLETE INFORMATION FOR |
| | STORM PANELS. SEE ATTACHED POLICY OR |
| | APPLY UNDER A SEPARATE PERMIT. |
| | 11-PROVIDE AT LEAST ONE BATHROOM WITH A |
| | DOOR THAT HAS A 29" CLEAR OPENING. |
| | SECTION 11 OF FLORIDA ACCESSIBILITY |
| | CODE FOR BUILDING CONSTRUCTION, 1997. |
| | 12-PROVIDE PRODUCT APPROVAL FOR: |
| | A)ROOF TILE. B)EXTERIOR DOORS AND |
| | WINDOWS, INCLUDING ARCHED WINDOWS AND |
| | FIXED WINDOWS. C)GARAGE DOORS. D)BUTT |
| | GLAZING ASSEMBLY AS SHOWN ON PLANS. |
| | E)FIREPLACE. F)GLASS BLOCK. G)BBQ UL |
| | LISTING. H)WINDOW MULLIONS. |
| | 13-PROVIDE COMPLETE SPECIFICATIONS FOR |
| | STUCCO APPLICATION AT ENTRY AND REAR |
| | PORCH AS REQUIRED BY ASTM C 926 AND |
| | ASTM C1063.SEC. 2504.2 SBC 1997. |
| | 14-TRUSS ANCHOR SCHEDULE NEED TO BE |
| | UPDATED. SEMCO AND HUGHES ARE NOT |
| | LONGER IN BUSINESS. USP BOUGHT THEM. |
| | 15-SEE PLANS FOR ADDITIONAL COMMENTS AND |
| | PLEASE RETURN REVIEWED SET OF PLANS |
| | AFTER CORRECTIONS ARE DONE TO THE |
| | ORIGINAL DRAWINGS IN ORDER TO EXPEDITE |
| | THE REVIEW PROCESS. |