 *******************DENIED***************
  
  
 CFM DISTRIBUTION ON PLAN SHEET 5 OF
 6 INDICATES 1500 CFM.MANUAL J
 CALCULATIONS INDICATE 1248 FOR A 3
 TON UNIT.PROVIDE MANUFACTURER
 SUBMITTAL DATA FOR THE 3 TON UNIT.
  
  
 IF YOU HAVE ANY QUESTIONS, PLEASE
 CONTACT PATTY KRAUSS AT 659-8096
 EXT. 8388.