2002-01-25 00:00:00BUILDING PLAN REVIEW
 *******DENIED*******
 ROBERT BROWN(561) 659 8096 EXT 8499
  
 SBC = STANDARD BUILDING CODE 1997
 SBC*= STANDARD BUILD'G CODE (CITY AMEND)
 FL ACC CODE = FLORIDA ACCESSIBILITY CODE
  
 FOR CONSISTENCY, THE FOLLOWING COMMENTS
 ARE NUMBERED AS PER THE BUILDING PLAN
 REVIEW OF 12/20/01:
  
 2) --PROVISO--
 CONTRARY TO THE REVIEW RESPONSE LETTER
 DATED 1/14/02 NO NOTICE OF COMMENCEMENT
 WAS "ATTACHED".A RECORDED COPY OF THE
 NOTICE OF COMMENCEMENT MUST BE SUBMITTED
 BEFORE A PERMIT CAN BE ISSUED.
  
 3) --PROVISO--
 CONTRARY TO THE REVIEW RESPONSE LETTER
 DATED 1/14/02 NO ROOF PERMIT APPLICATION
 WAS "ATTACHED".A SEPARATE ROOFING
 PERMIT IS REQUIRED (SBC* 104.1.1)
  
 7) FL ACC CODE 4.8.5(2) THE RAMP
 HANDRAILS SHALL EXTEND AT LEAST 18"
 BEYOND THE SLOPED SEGMENT AT THE BASE OF
 THE RAMP.
  
 9) SBC* 1804.2.2CONTRARY TO THE REVIEW
 RESPONSE LETTER DATED 1/14/02, NO
 GEOTECHNICAL REPORT WAS "ATTACHED".
 SUBMIT A COPY OF THE REPORT
  
 **QUOTE PERMIT# ON ALL CORRESPONDENCE**
  
 END OF REVIEW COMMENTS
 THE CODE REFERENCES GIVE ADDITIONAL INFO
 IF YOU HAVE ANY QUERIES PLEASE CALL:
 ROBERT BROWN(561) 659 8096 EXT 8499