| Plan Review Notes For Permit 01110799 |
| Permit Number |
01110799 |
|
| Review Stop |
R |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2002-01-12 00:00:00 | ************BUILDING PROVISO************ | | | | | | 1) STRUCTURE IS LOCATED IN AN A8 FLOOD | | | ZONE, AN ELEVATION CERTIFICATE IS | | | REQUIRED. | | | | | | 2) RESUBMIT STORM PANEL INFORMATION WITH | | | MASTERED DRAWINGS. THE ONES SUBMITTED | | | ARE COPIES OF ENGINEERED DRAWINGS THAT | | | WERE VALID FOR ONE PERMIT, AS INDICATED | | | BY THE NOTE ON THE DRAWINGS. | | | | | | 3) ONE WINDOW IN THE MASTER BEDROOM MUST | | | PROVIDE A NET CLEAR OPENING AREA OF 5.7 | | | SQ.FT., CLEAR OPENING HEIGHT NO LESS | | | THAN 24" AND CLEAR OPENING NO LESS THAN | | | 20". | | | | | | 4) REVISE THE TYPICAL EXTERIOR CEILING | | | DETAIL TO COMPLY WITH ASTM C-1063, WHICH | | | REQUIRES FASTENERS TO PENETRATE | | | HORIZONTAL FRAMING 1-3/4". (2"STAPLES) |
|