| Date |
Text |
| 2002-08-24 00:00:00 | |
| | BUILDING PLAN REVIEW |
| | PERMIT: 01110637 |
| | ADD: 4600 N FLAGLER |
| | CONT:ANDERSON-MOORE CONST |
| | TEL: (561)627-4744 |
| | FL BLD CODE= 2001 FLORIDA BUILDING CODE |
| | |
| | 1) THE PROBLEM PLAN REVIEW IS HAVING IN |
| | APPROVING YOUR PLAN, THE NOTES INDICATE |
| | (2) SCENARIOS, EITHER WE COUNT THIS AS |
| | 1 BUILDING WITH ADDITION OR 2 SIDE BY |
| | SIDE. |
| | |
| | 2) IF WE COUNT THIS AS ONE BUILDING THE |
| | FIRE DEPARTMENT IS LOOKING FOR FIRE |
| | SPRINKLERS, THE NEW STAIRS STILL NEED TO |
| | COMPLY WITH LIFE SAFETY CODE BUT WE CAN |
| | COUNT THE EXISTING HANDICAPPED RAMP AS |
| | A MEANS OF EGRESS FOR THE BUILDING. |
| | |
| | 3) IF WE COUNT THIS AS A NEW BUILDING, |
| | THE NEW STRUCTURE DOES NOT NEED TO BE |
| | FIRE SPRINKLER, WE DO NEED A ACCESSIBLE |
| | RAMP TO THIS STRUCTURE, AND THE STAIRS |
| | THOUGH THEY MEET THE BLDG CODE, WITH |
| | A 2R+1T= 24/25", THE LIFE SAFETY CODE |
| | DOESN'T ALLOW A 14" TREAD, A 13" TREAD |
| | IS ALLOWED, T(13) + (2) 5 1/2(R)= 24" |
| | WHICH WOULD SATISFY BOTH CODES. |
| | |
| | 4) NOT MENTIONED IN THE FIRST REVIEWS |
| | TO REMEMBER TO MAKE A PORTION OF THE |
| | PICNIC TABLES ACCESSIBLE FOR THE HANDI- |
| | CAPPED. |
| | |
| | 5) REQUIREMENTS FOR RAMPS ARE ATTACHED |
| | PLAN REVIEW OF 7/29/02 |
| | |
| | BEFORE A PERMIT TO CONSTRUCT, MAY |
| | BE ISSUED, IMPACT FEES MUST BE PAID TO |
| | PALM BEACH COUNTY. THE ACTUAL PERMIT |
| | SET OF PLANS MUST BE STAMPED BY THAT |
| | OFFICE, AND A COPY OF THE PAID RECEIPT |
| | ATTACHED TO THE PERMIT APPLICATION. |
| | PLEASE CALL (561)233-5025 FOR MORE |
| | INFORMATION. |
| | |
| | LOOK FOR COMMENTS BY THE OTHER PLAN |
| | REVIEW DISCIPLINES THAT MAY BE WRITTEN |
| | ON THE APPLICATION, PLANS, OR ATTACHED |
| | SEPARATELY. WHEN RESUBMITTING PLANS |
| | PLEASE CLEARLY INDICATE THE REVISION AND |
| | REMOVE AND REPLACE ANY PAGES AS NECESS- |
| | ARY. A TRANSMITTAL LETTER LISTING THE |
| | ORIGINAL REVIEW COMMENT NUMBER, WITH A |
| | DESCRIPTION OF THE REVISION MADE, IDEN- |
| | TIFYING THE SHEET OR SPECIFICATION PAGE |
| | WHERE THE CHANGES CAN BE FOUND, WILL |
| | HELP TO EXPEDITE YOUR PERMIT. THANK YOU |
| | FOR YOUR ANTICIPATED COOPERATION. |
| | JIM WITMER |
| | PLAN REVIEW |
| | TEL: (561)659-8096 EX.8412 |
| | FAX: (561)659-8026 |