| Plan Review Notes For Permit 01110574 |
| Permit Number |
01110574 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-11-20 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FACBC-97 | | | | | | 1) SPC SEC 407.2.2 REQUIRED FACILITIES | | | SHALL BE DIRECTLY ACCESSIBLE TO THE PUB- | | | LIC THROUGH DIRECT OPENINGS OR CORRIDORS | | | FROM THE AREA OR AREAS THEY ARE INTENDED | | | TO SERVE. DOOR OPENING NOT ACCEPTABLE. | | | PAGE A-1 | | | | | | 2) PAGE A-1, OFFICE DOORS TO OFFICE | | | SHALL NOT OPEN INTO CLEAR FLOOR SPACE OF | | | SINK PER FACBC SEC 4.22.2 | | | | | | 3) PAGE A-1, PER SPC TABLE 407 1 DRINK- | | | ING FOUNTAIN IS REQUIRED. D.F SHALL COM- | | | PLY WITH FACBC SEC 4.15. IF A SINGLE D. | | | F. IS USED PROVISIONS SHALL BE MADE FOR | | | THOSE WHO HAVE DIFFICULTY BENDING OR | | | STOOPING PER FACBC SEC 4.1.3(10). | | | | | | 4) PAGE M-1, WATER PIPING DIAGRAM. IF | | | W/HEATER HAS EMERGENCY PAN, IT SHALL | | | HAVE A 1" DRAIN LINE. AIR CHAMBERS ARE | | | QUICK FIX AND REQUIRE ACCESS PANELS AND | | | SHALL BE RECHARGEABLE PER SPC SEC 607.8. | | | 3. WATER HAMMER ARRESTORS CAN BE INSTALL | | | ED WITH OUT ACCESS PANELS. | | | | | | REVIEW BY KENSTEVENS | | | (561) 659-8096 EXT 8377 |
|