| Plan Review Notes For Permit 01110409 |
| Permit Number |
01110409 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2002-02-08 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FHA AMEND-98 DESIGN | | | MANUAL | | | | | | 1) SHT A0.11 UNIT TYPE A, INDICATE SPEC- | | | IFICATION A OR B FOR BATHROOM AS REQUES- | | | TED IN PREVIOUS PLAN REVIEW. | | | 2) SHT A0.11 HAS SPECIFICATION B LAY OUT | | | AND SPEC. A CALLED OUT. TYPICAL FOR RM | | | #'S B201, A101, AND C101. PLEASE CLAIRFY | | | 3) SHT A0.11 CLEAR FLOOR SPACE NOT SHOWN | | | ON KITCHEN FIXTURES AND/OR APPLIANCES AS | | | REQUIRED IN FHA DESIGN MANUAL. | | | 4) SHT A0.11 SHOW CLEAR FLOOR SPACE FOR | | | ALL LAVS WHICH SHALL BE CENTERED ON | | | CLEAR FLOOR SPACE, AND SHOW CLEAR FLOOR | | | SPACE PROPERLY AT ALL TUBS AND SHOWERS. | | | SEE FHA DESIGN MANUAL FOR EXAMPLES. | | | 5) SHT A0.11 ALL DIMENSIONS FOR WATER | | | CLOSETS NOT SHOWN. SEE B-307 AN C-110. | | | SHOWN IS 15" TO CENTER FROM ONE SIDE BUT | | | NO MEASUREMENT FROM OTHER SIDE. 33" MIN. | | | REQUIRED. | | | 6) SHT 2.12 SHOW ALL CLEANOUTS ON RISER | | | DIAGRAM, | | | 7) SHT P5.11 SANITARY RISER (B-2) STILL | | | REDUCES FROM 3" TO 2" ON RISER. 3" SHALL | | | RUN UNDIMINISHED FROM CONNECTION TO BLDG | | | DRAIN TO CONNECTION TO STACK VENT. | | | SPC SEC 714.2 | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|