| 2002-03-26 00:00:00 | BUILDING PLAN REVIEW |
| | PLAN REVIEW # 01110407 |
| | CLUBHOUSE |
| | |
| | SBC= 1997 STANDARD BUILDING CODE |
| | |
| | 1)- FLORIDA ENERGY CODE 1997 EDITION |
| | 400.0 FLORIDA ENERGY CODE REQUIRES |
| | ENERGY CODE COMPLIANCE METHOD A WHOLE |
| | BUILDING, CODE CALCULATIONS INCLUDING |
| | MANUAL J. |
| | |
| | 2)- SBC 1606.2.6.2 COMPONENTS & CLADDING |
| | THREE COPIES OF ALL PRODUCT ACCEPTANCE |
| | TESTING REPORTS SHALL BE REQUIRED FOR |
| | ALL GLAZED OPENINGS, EXT DOORS,SKYLIGHTS |
| | GLASS BLOCK, STORM SHUTTERS AS WELL AS |
| | ROOFING ASSEMBLIES. WHEN REPORTS ARE NOT |
| | FILED WITH THE PLANS AND THE BUILDING |
| | IS APPROVED, THE STIPULATION THAT A |
| | SEPERATE PERMIT WITH ASSOCIATED FEES |
| | SHALL BE REQUIRED, ALSO THE CITIES |
| | GUIDE LINES FOR LARGE PROJECTS REGARDING |
| | PROTECTION FOR ALL GLAZED OPENINGS SHALL |
| | BE ADHERRED TO, SEE ATTACHED GUIDELINES. |
| | THE BUILDING OFFICIAL SHALL REVIEW & |
| | APPROVE ALL PROPOSED ALL PROPOSED PRE- |
| | STORM PREPERATION PLAN. |
| | |
| | 3)-THE TRUSS & GIRDER LAYOUT DOES NOT |
| | INDICATE THE UPLIFT LOADSTO BE RESISTED. |
| | THEREIS A ANCHOR SCHEDULE INDICATING |
| | WHAT TYPE OF ANCHOR IS TO BE USED. WITH |
| | OUT THIS INFORMATION BEFORE THE ISSUANCE |
| | OF A BUILDING PERMIT THE ARCHETECT AND |
| | ENGINEER SHALL BE REQUIRED TO REVIEW THE |
| | TRUSS PLAN LAYOUT WITH THE TRUSS ENGIN- |
| | EERING CERTIFYING BY AFFIDAVIT THAT THIS |
| | TRUSS LAYOUT AND ATTACHMENT SHALL ALL |
| | THE REQUIREMENTS OF THE CODE. |
| | ANCHOR SSCHEDULE INDICATES: |
| | H-16 ALLOWABLE @160% 1475 UPL. NOT 1600 |
| | HGT 4 ALLOWABLE @160 9250 UPL NOT 9685 |
| | |
| | CONTRACTOR TO TRANSPORT PLANS TO COUNTY |
| | FOR IMPACT FEE ASSESSMENT. |
| | |
| | BUILDING PLAN REVIEW |
| | (561)659-8096X 8412 |
| | JIM WITMER |