| Plan Review Notes For Permit 01110407 |
| Permit Number |
01110407 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2002-02-09 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FACBC-97 | | | | | | 1) FROM PREVIOUS REVIEW, SH A2.61 PLEASE | | | PROVIDE DETAIL FOR SERVICE BAR SINK SHOW | | | COMPLIANCE WITH FACBC SEC 4.24 | | | 2) SHT A7.61 EACH PUBLIC OR COMMON USE | | | FACILITY SHALL COMPLY WITH FACBC SEC | | | 4.22, TOILET ROOMS 114 & 115. SHOW CLEAR | | | FLOOR SPACE, LAV TO BE CENTERED IN FLOOR | | | SPACE MIN. 15" OFF WALL TO CENTER. | | | 3) SHT A7.61 DOORS SHALL NOT SWING INTO | | | CLEAR FLOOR SPACE 4.17.5/4.22.2 OF ANY | | | FIXTURE OR THE TURNING RADIUS 4.22.3. | | | 4) SHT A7.61 PLEASE SHOW CLEAR FLOOR | | | SPACE FOR ALL HDCP FIXTURES. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT 8377 |
|