| 2001-11-21 00:00:00 | FAILED : |
| | SHEET 2, PAVING & GRADING NOTES; |
| | NOTE # 8 , ALL OFF-STREET PARKING STALL |
| | MUST BE STRIPED WITH DOUBLE 4" PAINTED |
| | STRIPES PER CITY OF WPB.PLEASE REVISED |
| | DETAILS ON SHEET 12. |
| | SHEET 2, SANITARY SEWER NOTES; |
| | NOTE # 8, ALL DUCTILE IRON PIPES USED |
| | FOR GRAVITY MAIN MUST BE A MIN. OF CLASS |
| | 51, PLEASE VERIFY. |
| | NOTE # 3, ALL SANITARY SEWER MAIN AND |
| | SERVICE LATERALS SHALL BE CONSTRUCTED OF |
| | PVC PIPE WITH RING-TITE JOINTS , ASTM |
| | D-3034-SDR 26. |
| | NOTE # 6, PVC SEWER FITTING SHALL |
| | CONFORM TO THE REQUIREMENT OF ASTM |
| | D-3034 STANDARD WITH MIN. WALL THICKNESS |
| | OF SDR26. |
| | ALL BACKFLOW PREVENTERS MUST BE APPROVED |
| | BY PUBLIC UTILITIES DEPT. CITY OF WPB |
| | 659-8040. |
| | A SEPARATE PERMIT AND APPROVAL FROM |
| | PUBLIC UTILITIES DEPT. FOR ALL NEW |
| | CONNECTIONS IS REQUIRED,659-8040. |
| | CONTRACTOR TO CONTACT RODNEY COMPO FOR |
| | INSTALLATION/ INSPECTION OF GREASE TRAP, |
| | 837-4051 EXT. 4074. |
| | ANY WORK WITHIN PUBLIC R.O.W WILL |
| | REQUIRE APPROVAL AND PERMIT FROM CITY |
| | ENGINEER'S OFFICE, 659-8040. |
| | SEPARATE PERMIT FOR UNDERGROUND |
| | UTILITIES/SITE WORKS IS RECOMMENDED AT |
| | THE TIME OF ACTUAL PERMITTING. |
| | IF ANY QUESTIONS PLEASE CONTACT 659-8096 |
| | EXT. 8492 MOHAMMAD R. AMINI |