Plan Review Notes
Plan Review Notes For Permit 01101103
Permit Number 01101103
Review Stop B
Sequence Number 2
Notes
Date Text
2001-12-19 00:00:00SECOND CHECKLIST:
 1-OWES $11.22 FOR ADJUSTED VALUE AND
 RADON FEES. PLEASE, BRING COPY OF
 PAID RECEIPT.
 2-NEED TO RECORD NOTICE OF COMMENCEMENT
 IN THE COURTHOUSE BUILDING.
 3-ENGINEER TO RE-REVISE THE DESIGN
 CERTIFICATION FOR BUILDING CODE
 COMPLIANCE FORM. ENGINEER DIDN'T SEE
 REFERENCED TABLES IN SBC 1997 IN ORDER
 TO APPLY THE CORRECT IMPORTANCE FACTOR
 AND BASIC VELOCITY PRESSURE.
 **ENGINEER TO PROVIDE ALL HIS INFORMAT'N
 AT THE BOTTOM OF FORM, INCLUDING
 CERTIFICATION # AS REQUIRED BY CHAPTER
 471 OF FLORIDA STATUTES.
 **ENGINEER TO SPECIFY PROJECT NAME AND
 ADDRESS ON TOP OF FORM.
 4-ENGINEER TO PROVIDE COMPLETE SPECS FOR
 STRUCTURAL GUTTER. THIS IS PART OF HIS
 DESIGN AND SHALL BE PART OF HIS SIGNED
 AND SEALED DRAWINGS. (SPECIFY GUTTER
 MATERIALS AND THICKNESS). SECTION
 104.2.2 CITY AMENDMENTS TO SBC 1997.
 INFORMATION SUBMITTED IS ONLY THE
 SALES BROCHURE.
 5-PROVIDE DETAIL SHOWING ATTACHMENT OF
 2X6 & 2X5 BEAM TO THE WALL & TO COL.
 6-CLEARLY INDICATE ON ENGINEERED DWGS
 ALL THE COMPONENTS THAT APPLY FOR
 THIS PROJECT.


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved