| 2001-12-18 00:00:00 | *************BUILDING UNSAT************* | | | | | | 1) IMPACT FEES MUST BE PAID TO PALM | | | BEACH COUNTY, PLANS STAMPED BY THEM AND | | | COPY OF RECEIPT SUBMITTED TO CITY OF | | | WEST PALM BEACH BUILDING DEPARTMENT, | | | BEFORE A BUILDING PERMIT CAN BE ISSUED. | | | | | | 2) A RECORDED COPY OF THE NOTICE OF | | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | | PERMIT CAN BE ISSUED. | | | | | | 3)PROVIDE (2) CURRENT AND COMPLETE | | | COPIES OF SBCCI OR METRO-DADE PRODUCT | | | APPROVALS FOR: | | | - FRONT DOOR (DOOR WITH SIDELITE) | | | | | | 4) THE ARCHED FIXED GLASS WINDOW AT THE | | | DINING ROOM IS LARGER THAN THE MAXIMUM | | | SIZE ALLOWED BY THE PRODUCT APPROVAL FOR | | | PGT SERIES PW-701 ALUMINUM FIXED WINDOW. | | | | | | 5) THE LARGE FIXED GLASS WINDOW AT THE | | | LIVING ROOM EXCEEDS THE CAPACITIES OF | | | THE MULLION PRODUCT APPROVALS. THE TWO | | | RECTANGULAR WINDOWS JOINED BY MULLIONS, | | | EACH EXCEED THE MAXIMUM SIZE LISTED IN | | | THE PRODUCT APPROVALS FOR PGT SERIES | | | F-6000 FIXED WINDOWS. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|