2002-01-09 00:00:00TRUSSES DENIED
  
 1) THE DESIGN CRITERIA LISTED ON THE
 TRUSS DRAWINGS IS INCORRECT. THE
 ACCEPTED DESIGN CRITERIA FOR THE CITY OF
 WEST PALM BEACH IS ASCE 7-95 (145MPH) OR
 1997 SBC (STANDARD BUILDING CODE)
 SECTION 1606 (110 MPH). THE STRUCTURE IS
 DESIGNED TO ASCE 7-95, THEREFORE THE
 TRUSSES MUST BE DESIGNED TO ASCE 7-95,
 AND NOT TO 97 SBC.
  
 2) THE TRUSS LAYOUT LISTS THE WIND
 DESIGN VELOCITY AS 110 MPH. THIS DOES
 NOT CORRESPOND WITH THE TRUSS DRAWINGS
 (145 MPH) OR THE PLANS. PLEASE CORRECT.
  