| 2001-10-30 00:00:00 | CHECKLIST: |
| | 1-NEED TO RECORD NOTICE OF COMMENCEMENT |
| | WITH THE COURHOUSE. |
| | 2-AFTER ORIGINAL DRAWINGS ARE REVISED, |
| | PLEASE BRING THEM TO PALM BEACH COUNTY |
| | TO PAY IMPACT FEES. BRING STAMPED |
| | DRAWINGS AND PAID RECEIPT. |
| | 3-DESIGN CERTIFICATION FOR BUILDING CODE |
| | COMPLIANCE FORM IS INCOMPLETE: |
| | A)INDICATE EXPOSURE CONDITION. |
| | B)REVISE THE IMPORTANCE FACTOR: SEE |
| | ASCE 7-95 TABLE 6-2. |
| | C)ENGINEER DIDN'T SIGN THE FORM. |
| | |
| | 4-THIS PROPERTY IS LOCATED ON FLOOD ZONE |
| | A-5. PROVIDE SURVEY SHOWING EXISTING |
| | FINISH FLOOR ELEVATIONS TO VERIFY THAT |
| | LOWEST FLOOR IS 6" ABOVE THE BASE |
| | FLOOD ELEVATION. SEC. 12-22(B)(1) OF |
| | CITY CODE. |
| | 5-PROVIDE SITE PLAN SHOWING LOCATION OF |
| | GARAGE IN RELATION TO PROPERTY LINE TO |
| | CHECK FOR TABLE 600 SBC 1997. |
| | 6-PROVIDE COMPLETE FASTENING SPECS FOR |
| | ATTACHMENT OF NEW PORTION OF CHIMNEY |
| | TO EXISTING ONE. |
| | -ALSO, CHIMNEY DETAIL/SECTION DOESN'T |
| | MATCH THE ONE SHOWN ON EXT. ELEVATIONS |
| | -PROVIDE PRODUCT APPROVAL AND SPECS FOR |
| | "DUROCK" MATERIAL USED AS WALL AND |
| | ROOF SHEATHING MATERIAL. |
| | 7-REVISE GENERAL NOTES. THEY SAY THAT |
| | THE DESIGN CRITERIA IS SSTD 10-97, BUT |
| | DESIGN CERTIFICATION FOR BUILDING CODE |
| | COMPLIANCE FORM SEALED BY THE ENGIN'R |
| | USES ASCE 7-95 FOR 150 MPH WIND LOAD. |
| | SSTD 10-97 IS NOT A BUILDING CODE. IT |
| | IS A DESIGN PRESCRIPTIVE METHOD USED |
| | WHEN THE DESIGNER IS NOT A REGISTERED |
| | ARCHITECT OR ENGINEER. |
| | 8-SPECIFY SAFETY GLASS WHERE REQUIRED. |
| | SEE PLANS AND SECTION 2405.2 SBC 1997. |
| | 9-PROVIDE,2 COPIES,PRODUCT APPROVAL FOR: |
| | A)SPANISH TILE. |
| | B)FRENCH DOORS. |
| | C)SINGLE HUNG WINDOWS. |
| | D)ENTRY DOORS. |
| | E)UL LISTING AND SPECS FOR BBQ. |
| | F)GARAGE DOORS. |
| | 10-PROVIDE PRODUCT APPROVALS FOR STORM |
| | SHUTTERS. |
| | -PROVIDE KEY PLAN AND COMPLETE INSTALL- |
| | ATION SCHEDULE AS PER CITY SAMPLE. |
| | -CLEARLY IDENTIFY ON PRODUCT APPROVALS |
| | SPECIFIC MOUNTING CONDITIONS AND |
| | ANCHORS TO BE USED. |
| | 11-PROVIDE SMOKE DETECTORS BY STAIRS OF |
| | FLORIDA ROOM. SEC. 905.2 SBC 1997. |
| | 12-SPECIFY CONNECTORS AT TOP AND BOTTOM |
| | OF NEW 2X4 COLUMNS AT KITCHEN AREA. |
| | SEC. 104.2.2 CITY AMENDMENTS TO SBC/97 |
| | 13-SEE SECTION 1007 OF SBC 1997 AND |
| | PROVIDE ALL INFORMATION MISSING FOR |
| | STAIRS, RAILINGS, ETC. |
| | -SEE SECTION 2305 SBC 1997 AND PROVIDE |
| | THE SPECS FOR FIREBLOCKING. |
| | 14-PROVIDE COMPLETE SECTION/DETAIL THRU |
| | MASTER BEDROOM BALCONY. INCLUDE SPECS |
| | FOR GUARDRAILS AS REQUIRED BY SECTIONS |
| | 1015 AND 1608.2 SBC 1997. |
| | 15-PROVIDE BORING TEST. SEC. 104.2.2 OF |
| | CITY AMENDMENTS TO SBC 1997 AND |
| | GENERAL NOTES ON SHEET A-4. |
| | 16-PROVIDE ATTIC ACCESS AT MASTER BEDRM |
| | AND GUEST SUITE. SEC. 2309.6 SBC 1997 |
| | 17-REVISE ENERGY CALCULATIONS: |
| | -USE FORM 600A-97, NOT 600A-93. |
| | -SPECIFY SIZE OF CEILING FANS ON ELEC. |
| | PLANS FOR MASTER BEDROOM, FAMILY ROOM |
| | AND GUEST SUITE IF USING THE CEILING |
| | FAN CREDIT ON ENERGY CALCULATIONS. |
| | SEE TABLE 6-6 OF FLORIDA ENERGY CODE |
| | FOR BUILDING CONSTRUCTION, 1997 ED. |
| | 18-SEE PLANS FOR ADDITIONAL COMMENTS, |
| | INCLUDING THOSE BY THE OTHER TRADES. |
| | |
| | NOTE: PLEASE RETURN REVIEWED SET AFTER |
| | CORRECTIONS ARE DONE TO ORIGINAL |
| | DRAWINGS TO EXPEDITE THE REVIEW. |