| 2002-07-11 00:00:00 | THE SEVERAL AND VARIOUS METRO DADE | | | NOTICE OF ACCEPTANCES FOR THE DOORS AND | | | WINDOWS SUBMITTED AS SHOPDRAWINGS ON | | | 6/25/02 ARE REQUIRED TO HAVE A SEPARATE | | | PERMIT APPLICATION, SINCE THEY WERE NOT | | | INCLUDED WITH THE ORIGIANL PERMIT PLANS. | | | | | | | | | PLEASE INCLUDE A SKETCH INDICATING THE | | | LOCATION OF THE WINDOW OR DOOR TO BE | | | INSTALLED.SHOW THE DESIGN PRESSURES | | | FOR THE OPENINGS ON THE SKETCH.ENSURE | | | THAT THE PRESSURES ON THE NOA'S AGREE | | | WITH THE BUILDING DESIGN AND IN CASES | | | WHERE THERE IS MORE THAN ONE METHOD OR | | | UNIT ON THENOA THAT THE INTENDED METHOD | | | OR UNIT IS CLEARLY SELECTED AND MARKED | | | ON THE NOA. | | | | | | SOME OF THE NOA'S INDICATED THE | | | REQUIREMENT FOR "HURRICANE PROTECTION" | | | IE SHUTTERS.THE BUILDING OFFICIAL'S | | | INTERPRETATION OF THE CODE IS THAT | | | SHUTTERS ARE NOT TO BE SUBSTITUTED FOR | | | IMPACT RESISTANT GLAZING IN LARGE | | | BUILDINGS AND/OR LARGE NUMBERS OF | | | OPENINGS.SEE THE ATTACHED | | | IMPLEMENTATION STANDARD. |
|