| Date |
Text |
| 2001-10-23 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT # 01091467 |
| | 3500 45TH ST SUITE 18 |
| | CONT: HUMMUT CONSTRUCTION |
| | TEL: 965-9911 |
| | |
| | SBC= 1997 STANDARD BUILDING CODE |
| | SBC*= AMENDMENTS STANDARD BUILDING CODE |
| | |
| | 1)- SBC 503.2.3.2: MEZANINE VS A 2ND FL: |
| | WHEN THE FLOOR AREA IS OVER 1/3 THE |
| | FLOOR AREA OF THE ROOM IT IS LOCATED IN, |
| | THE AREA IS CONSIDERED A SECOND STORY |
| | WITHIN THE ENCLOSED SPACE. |
| | |
| | 2)- THE NEW SECOND FLOOR STORAGE AREA |
| | WILL NOT NEED TO MEET THE VERTICAL |
| | ACCESSIBILITY REQUIREMENTS, EXCEPTION |
| | TO STORAGE AREAS, CHANGE OF USE WILL |
| | ENVOKE FLORIDA ACCESSIBILITY REQUIREMENT |
| | |
| | 3)- SBC 104.2.2 ADDITIONAL INFORMATION |
| | REQUIRED? INFILL OF EXISTING STAIRS |
| | WITH WHAT TYPE OF MATERIAL? |
| | |
| | 4)- SBC 1604.1 THE PLANS SHALL INDICATE |
| | WHAT THE LIVE LOAD FLOOR LOADS ARE |
| | DESIGNED FOR, SECOND FLOOR LIGHT 125LBS |
| | /FT OR HEAVY 250 LBS/FL? |
| | |
| | 5)- SBC* STORAGE & FACTORY OCCUPANCIES: |
| | IT SHALL BE THE RESPONSIBILITY OF THE |
| | OWNER, AGENT, PROPRIETOR OR OCCUPANT OF |
| | GROUP S & GROUP F OCCUPANCIES, OR ANY OC |
| | CUPANCY WHERE EXCESSIVE IS LIKELY TO |
| | OCCUR, TO EMPLOY A COMPETENT ARCHITECT |
| | OR ENGINEER TO COMPUTE THE SAFE LOAD |
| | CAPACITY. ALL SAFE LOAD COMPUTATIONS |
| | SHALL BE ACCOMPANIED BY AN AFFIDAVIT |
| | FROM THE ARCHITECT OR ENGINEER STATING |
| | THE SAFE ALLOWABLE FLOOR LOAD ON EACH |
| | FLOOR IN POUND PER SQUARE FOOT UNIFORMLY |
| | DISTRIBUTED. THE COMPUTATIONS AND AFFIDA |
| | VIT SHALL BE FILED AS A PERMANENT RECORD |
| | OF THE BUILDING DEPARTMENT. |
| | |
| | 6)- SBC*106.4.3 SIGNAGE REQUIRED: |
| | IN EVERY BUILDING WHERE A PART OF THE |
| | BUILDING IS USED FOR STORAGE,THE SAFE |
| | FLOOR LOADS AS REVIEWED BY THE BUILDING |
| | OFFICIAL ON THE PLAN, SHALL BE MARKED ON |
| | PLATES OF APPROVED DESIGN WHICH SHALL BE |
| | SUPPLIED AND SECURELY AFFIXED BY THE |
| | OWNER IN A CONSPICUOUS PLACE FOR EACH |
| | STORY TO WHICH IT RELATES. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | (561) 659-8096X8412 |