| Plan Review Notes For Permit 01091364 |
| Permit Number |
01091364 |
|
| Review Stop |
B |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2001-12-10 00:00:00 | BUILDING PROVISO: | | | TRUSS ENGINEERING: | | | TRUSS ENGINEERING TO BE REVIEWED BY THE | | | ARCHITECT OF RECORD. | | | | | | TRUSS SHOP DRAWINGS ARE TO BE REVIEWED | | | BY BUILDING DEPARTMENT BEFORE ERECTION | | | OF TRUSSES. | | | | | | TRUSS ENGINEER TO COMPLY WITH STATE | | | STATUTE 61G15-31.003 STAMPED SIGNATURE | | | NOT ACCEPTTED. SEE ATTACHMENT. | | | | | | TRUSS ENGINEERING TO REFLECT THE SAME | | | DESIGN PERAMETERS AS BUILDING, EITHER | | | SBC 1997 AS AMENDED BY CWPB, 110 MPH OR | | | ASCE 7-95, 145 MPH SEE ATTACHMENT. | | | | | | INDIVIDUAL TRUSS ENGINEERING SHOWING | | | ASCE 7-88 OR 7-93. | | | | | | SBC 1606.2.4.2. TRUSS ENGINERING SHEETS | | | SHOW 2 ELEVATIONS, 12' & 18'. WHERE MORE | | | THAN ONE LOAD CASE EXISTS, BUILDINGS | | | SHALL BE DESIGNED FOR ALL LOAD CASES. |
|