2002-01-07 00:00:00DENIED
 REFERENCE: SPC-94-FACBC-97
  
 1) SHT P-1 ALL SIGNED AND SEALED PLANS
 SHALL HAVE ALL SHEETS SIGNED AND SEALED
 AND ARE REQUIRED TO HAVE A TITLE BLOCK
 ON THEM.
  
 2) SHT P-1 WATER RISER DIAGRAM AIR CHAM-
 BERS SHALL BE ACCESSIBLE AND RECHARGEA-
 BLE PER SPC SEC 607.8.3. SEE ATTACHED
 SHEET FOR APPROVED AIR CHAMBERS. APPROV-
 ED WATER HAMMER ARRESTORS DO NOT REQUIRE
 ACCESS AND ARE RECOMMENDED. SIZE AND
 LOCATION PER PDI-WH 201 IN AN EFFECTIVE
 RANGE CLOSE TO LAST FIXTURE NOT AT TOP
 OF DROP.
  