| 2001-11-03 00:00:00 | APPROVED WITH PROVISO: | | | 1-DESIGN CERTIFICATION FOR BUILDING CODE | | | COMPLIANCE FORM IS NOT COMPLETE WITH | | | THE REQUIRED INFORMATION. SEE | | | COMMENTS ON FORM SUBMITTED. | | | -NOTE: ENGINEER SEALING THIS FORM SHALL | | | SIGN AND SEAL THE STRUCTURAL DRAWINGS | | | AS WELL, SINCE HE IS ASSUMING THE | | | STRUCTURAL DESIGN FOR THIS HOUSE. | | | 2-PROVIDE COMPLETE INFORMATION FOR STORM | | | SHUTTERS UNDER A SEPARATE PERMIT. | | | 3-BEDROOM WINDOWS TO BE REPLACED NEED TO | | | MEET EGRESS REQUIREMENTS OF SECTION | | | 1005.4 SBC 1997: 24" MIN. CLEAR HEGHT | | | OPENING, 20" MIN. CLEAR WIDTH OPENING | | | AND 5 SQ. FT. MIN. TOTAL CLEAR OPENING | | | 4-BEFORE INSTALLATION PROVIDE PRODUCT | | | APPROVAL FOR: | | | A)FRENCH DOORS. | | | B)ENTRY DOOR WITH SIDELITES SINGLE | | | ASSEMBLY AS SHOWN ONPLANS. | | | C)WINDOW MULLIONS. | | | D)GARAGE DOORS THAT MEET THE DESIGN | | | PRESSURES SPECIFIED BY THE ARCHITECT. |
|