| 2002-05-10 00:00:00 | TRUSS DRAWINGS CHECKLIST: |
| | 1-TRUSS LAYOUT TO HAVE ENGINEER'S |
| | ORIGINAL SIGNATURE AS REQUIRED BY |
| | CHAPTER 471 OF FLORIDA STATUTES. |
| | **ALSO, ENGINEER TO INCLUDE ALL HIS |
| | INFORMATION AS REQUIRED BY CHAPTER |
| | 471 FLORIDA STATUTES. |
| | 2-ENGINEERED TRUSSES: |
| | A)ENGINEER TO HAVE ORIGINAL SIGNATURE, |
| | EMBOSSED SEAL AND DATE AS REQUIRED BY |
| | CHAPTER 471 OF FLORIDA STATUTES. |
| | B)ENGINEERED TRUSS TO HAVE SPECIFIC |
| | YEAR OF THE CODE USED FOR DESIGN. |
| | C)ENGINEER TO SIGN, SEAL AND DATE LETTER |
| | FOR LATERAL BRACING AS REQUIRED BY |
| | CHAPTER 471 FLORIDA STATUTES. |
| | D)REVISE/UPDATE ALL GENERAL TRUSS |
| | DETAILS. USE SBC (WITH SPECIFIC YEAR) |
| | FOR 110MPH OR ASCE 7-95 FOR 140MPH, |
| | NOT ASCE 7-93 FOR 110MPH.(SEE PACKAGE) |
| | E)ENGINEER TO SIGN, SEAL AND DATE ALL |
| | GENERAL TRUSS DETAILS AS REQUIRED BY |
| | CHAPTER 471 FLORIDA STATUTES. |
| | **NOTE: COPY OF GENERAL TRUSS DETAILS |
| | HAS THE SEAL OF ANOTHER ENGINEER. |
| | CLARIFY WHO IS RESPONSIBLE FOR THE |
| | DESIGN AS REQUIRED BY CHAPTER 471 |
| | FLORIDA STATUTES. |
| | SEE COMMENTS ON GENERAL TRUSS DETAILS. |
| | 3-ENGINEER OF RECORD TO REVIEW ALL |
| | TRUSS DRAWINGS AFTER CORRECTIONS ARE |
| | DONE TO THEM. USE STANDARD REVIEW |
| | STAMP OR ACCEPTABLE METHOD IDENTIFYING |
| | ENGINEER WHO REVIEW THE TRUSSES AS |
| | REQUIRED BY CHAPTER 471 FL. STATUTES. |