Plan Review Notes
Plan Review Notes For Permit 01090539
Permit Number 01090539
Review Stop R
Sequence Number 1
Notes
Date Text
2001-10-09 00:00:00*************BUILDING UNSAT*************
  
 1) THE ENERGY FORM INCORRECTLY LISTS THE
 EXTERIOR WALL TYPE AS WOOD FRAME WITH AN
 R VALUE OF 3.0. THE EXTERIOR WALLS ARE
 ACTUALLY CONCRETE BLOCK. PLEASE CORRECT.
  
 2) THE ROOF SHEATHING AT GABLE ENDS IS
 REQUIRED TO BE NAILED WITH 8D COMMON
 NAILS AT 4" O.C. AT THE EDGES AND 6"O.C.
 INTERMEDIATE WITHIN 5' OF THE ROOF EDGE
 INCLUDING OVERHANG. SEC.2306 CITY OF
 W.P.B. AMENDMENTS TO THE 97 S.B.C.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202