| Plan Review Notes For Permit 01090435 |
| Permit Number |
01090435 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2002-01-04 00:00:00 | DENIED | | | REFERENCE: SPC-94-FACBC-97 | | | | | | 1) SHT 2, TOILET ROOM TO BE ACCESSIBLE | | | AND DESIGNATED UNISEX HDCP TOILET ROOM. | | | TABLE 407 REQUIRES 2 W/C'S AND 2 LAVS | | | FOR WOMEN. | | | | | | 2) SHT 5, WATER RISER DIAGRAM, AIR CHAM- | | | BERS TO BE ACCESSIBLE AND RECHARGEABLE | | | PER PDI-WH 201 AND SPC SEC 607.8.3. | | | WATER HAMMER ARRESTORS DO NOT REQUIRE | | | ACCESS AND SHALL BE LOCATED CLOSE TO | | | SOURCE OF SHOCK. | | | | | | 3) SHT 2, DOOR SHALL NOT SWING INTO | | | CLEAR FLOOR SPACE OF FIXTURES 4.22.2. | | | | | | 4) SHT 2, PLEASE SHOW DETAILS FOR SINK | | | COMPLIANCE SEC 4.24 | | | | | | 5) SHT 5, NOTE #12 REMOVE REFERENCE TO | | | AIR CHAMBERS. | | | | | | REVIEW BY KEN STEVENS | | | (561) 659-8096 EXT. 8377 |
|