| 2001-09-24 00:00:00 | BUILDING PLAN REVIEW |
| | PERMIT # 01090294 |
| | 1649 FORUM PLACE |
| | CONT: BUILDING ASSOCIATES INC |
| | TEL: (561) 746-3421 |
| | CEL: (561) 310-5429 |
| | |
| | SBC = STANDARD BUILDING CODE |
| | |
| | 1)- SHEET A1 INDICATES EXTERIOR DOORS |
| | # 4,5 & 8. THERE IS NO PLOT PLAN, THE |
| | KEY PLAN DOESN'T INDICATE WHERE THE PROP |
| | ERTY LINE IS IN RELATIONSHIP WITH THESE |
| | OPENINGS. SBC 705 1.1.2. PROTECTION OF |
| | EXTERIOR WALL OPENINGS, EVERY EXTERIOR |
| | WALL OPENING WITHIN 15' OF THE PROPERTY |
| | LINE SHALL BE EQUIPPED WITH APPROVED |
| | OPENING PROTECTIVES. |
| | |
| | 2)- SHEET A1 INDICATES THAT THERE WAS A |
| | DOORWAY BLOCKED IN AT APPROXIMATELY |
| | DOOR #5, IS DOORWAY #5 A NEW OPENING RE- |
| | QUIRING THE LINTEL? IF SO DO THE BLOCK |
| | CELLS ON EITHER SIDE OF THE DOORWAY |
| | REQUIRE REINFORCING? |
| | |
| | 3)- SHEET A1 ALSO INDICATES THAT DOOR |
| | #4 IS TO BE REPLACED, WILL THE DOOR JAMB |
| | ALSO BE REPLACED? |
| | |
| | 4)- SBC 1606.2.6.2 COMPONENTS & CLADDING |
| | EXTERIOR DOOR ASSEMBLIES (DOOR & JAMBS) |
| | THAT ARE REPLACED SHALL COMPLY WITH |
| | WIND ZONE TESTING REQUIREMENT TESTING. |
| | 110 MPH WIND ZONE. THE CITY ACCEPTS |
| | DADE COUNTY OR SBCCI TEST REPORTS, |
| | (2 COPIES). |
| | |
| | 5)- SBC 1205 RODENT PROOFING, EXTERIOR |
| | WALL OPENINGS TO COMPLY WITH THIS SEC- |
| | TION OF THE CODE. |
| | |
| | 6)- SHEET A1 INDICATES THAT THERE WILL |
| | BE NEW GLAZING (WINDOW) THE CITY SHALL |
| | REQUIRE PRODUCT TESTING REPORTS,THE TEST |
| | ING REPORT WILL NEED ONLY SHOW TESTING |
| | FOR WIND, SINCE LESS THAN 50% OF THE |
| | GLAZED OPENINGS ARE NOT BEING REPLACED |
| | THIS STRUCTURE DOES NOT REQUIRE NEED TO |
| | MEET THE REQUIREMENTS FOR LARGE MISSLE |
| | IMPACT GLAZING. SBC 1606.4/1707/4/1. |
| | CITY OFFICIAL INTERPRETATION (4). |
| | |