| 2001-09-12 00:00:00 | *******************PROVISO************** | | | | | | | | | EF-1 SHALL TERMINATE A MINIMUM OF 10' | | | ABOVE ADJOINING GRADE LEVEL, 10' FROM | | | ANY ADJACENT BUILDING, PARKING AREA, | | | PROPERTY LINE, WINDOW, DOOR, OR AIR | | | INTAKE. 1997 SMC 506.1. | | | | | | NFPA 96 4-8.3.1, THE CLOSET POINT OF ANY | | | WINDOW ABOVE EXHAUST SHALL BE A MINIMUM | | | OF 10' DISTANT, PLUS 0.25 FOR EACH ONE | | | DEGREE FROM HORIZONTAL, ANGLE BEING | | | MEASURED FROM THE CENTER OF THE EXHAUST | | | TERMINATION TO THE CENTER OF THE WINDOW. | | | | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | PATTY KRAUSS AT 659-8096 EXT. 8388. |
|