| Date |
Text |
| 2001-10-24 00:00:00 | *************BUILDING UNSAT************* |
| | |
| | 1) IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| | |
| | 2) THE EXTERIOR WALL SECTION, C ON SHEET |
| | A-3.0, INDICATES THE THE EXTERIOR |
| | FOUNDATION BEARING 12-INCHES BELOW FINAL |
| | GRADE. THE SOIL TEST REPORT REQUIRES THE |
| | EXTERIOR FOUNDATIONS TO BEAR 14-INCHES |
| | BELOW OUTSIDE FINAL GRADE. PLEASE |
| | CORRECT. |
| | |
| | 3) THE INFORMATION PROVIDED DOES ALLOW |
| | FOR ACCESS TO REAR YARDS OF UNITS, HOW- |
| | EVER IT DOES NOT ADDRESS THE OTHER |
| | ISSUES. THE ACCESS DOOR CAN STILL BE |
| | BLOCKED BY SHRUBBERY, FENCE, POOL OR |
| | OTHER BARRIER INSTALLED BY ADJACENT |
| | PROPERTY OWNER. |
| | THE DOOR WILL ALSO ALLOW DIRECT ACCESS |
| | TO THE ADJOINING REAR YARD, WHICH WILL |
| | BE A PROBLEM IF A POOL IS INSTALLED. |
| | POOLS ARE REQUIRED TO HAVE AN ENCLOSURE |
| | NOT LESS THAN 4 FEET ABOVE THE |
| | UNDERLYING GROUND SUFFICENT TO MAKE IT |
| | INACCESSIBLE TO SMALL CHILDREN. SEE CITY |
| | OF W.P.B. SWIMMING POOL CODE. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)659-8096 EXT.8202 |
| | |
| | |
| | TRUSSES |
| | UNSAT |
| | |
| | 1) THE UPLIFT VALUES ON PAGE S-2 ARE |
| | INNCORRECT. THE UPLIFT FOR MARK TA-10, |
| | A TAPR216 FOR 160% IS 1485# NOT 1485# AS |
| | INDICATED IN THE ANCHOR SCHEDULE ON THE |
| | PLANS. |
| | |
| | 2) RTPGA MODEL TRUSS ANCHORS ARE NO |
| | LONGER AVAILABLE FROM USP, WHO HAVE |
| | BOUGHT OUT SEMCO AND HUGHES. PLEASE |
| | UPDATE THE TRUSS ANCHOR SCHEDUE. |
| | |
| | 3) PLACING (2) STRAPS ON A TRUSS WILL |
| | NOT DOUBLE THE UPLIFT CAPACITY. FOR |
| | INSTALLATIONS SPACED CLOSER THAN 8" |
| | CENTER TO CENTER CONSULT USP FOR REDUCED |
| | LOAD VALUES. |
| | |
| | 4) THE USC3F TRUSS & ANCHOR TIEDOWN WITH |
| | TWO 3/4"X 6" WEDGE BOLTS IS RATED FOR |
| | 6170# OF UPLIFT. TRUSS GT11 HAS AN |
| | UPLIFT OF 6970#, WHICH EXCEEDS THE |
| | CAPACITY OF THE SPECIFIED ANCHOR. THIS |
| | ANCHOR WILL WORK WITH HEEL HEIGHTS UP TO |
| | 14", HOWEVER THE HEIGHT OF GT11 IS 2"4". |
| | PLEASE CORRECT. |
| | |
| | 5) THE NOTE ON THE TRUSS LAYOUT SPECIFY- |
| | ING THE HANGERS TO BE USED IS ILLEGIBLE. |
| | PLEASE CLARIFY. |