| Date |
Text |
| 2002-05-02 00:00:00 | BUILDING REVISION DENIED |
| | |
| | 1) ADDITIONAL IMPACT FEES MAY BE DUE TO |
| | PALM BEACH COUNTY. REVISED PLANS MUST BE |
| | REVIEWED BY THE COUNTY, STAMPED BY THEM |
| | AND A COPY OF THE RECIEPT SUBMITTED TO |
| | THE CITY OF WPB BEFORE THE REVISION CAN |
| | BE APPROVED. |
| | |
| | 2) REVISED ENERGY CALCULATIONS AND |
| | MANUAL "J" CALCULATIONS ARE REQUIRED. |
| | |
| | 3) THE ORIGINAL PLANS WERE DESIGNED |
| | USING THE 1997 SBC CRITERIA AND 110 MPH |
| | WIND SPEED. THE REVISION IS USING THE |
| | 2001 FBC AND A 140 MPH WIND SPEED. THE |
| | REVISION MUST USE THE SAME DESIGN |
| | CRIETRIA AS THE PERMITTED PLANS. |
| | |
| | 4) THE PLAN NOTES, FRAMING NOTES AND |
| | FOUNDATION NOTES ON C1 HAVE BEEN CHANGED |
| | FROM THE APPROVED PLANS. |
| | |
| | 5) PROVIDE PRODUCT APPROVALS FOR THE |
| | MULLIONS CONNECTING THE 16' SLIDING |
| | GLASS DOOR AND FIXED GLASS WINDOWS AT |
| | THE GREAT ROOM OR PROVIDE ENGINEERING |
| | FOR THIS ASSEMBLY. |
| | |
| | 7) PROVIDE REVISED KEY PLAN AND |
| | INSTALLATION SCHEDULE FOR STORM PANELS. |
| | |
| | 8) THE EGRESS WINDOW AT THE PROPOSED DEN |
| | EXCEEDS THE OPENING AREA ALLOWED BY |
| | TABLE 600 OF THE 97 SBC. BASED ON THE |
| | DISTANCE TO THE PROPERTY LINE 20 PERCENT |
| | OF THE WALL AREA (20.68 SQFT.)IS ALLOWED |
| | |
| | 9) DETAIL 6 ON A5 INDICATES A 45 DEGREE |
| | OFFSET HANGER. DUE TO THE REVISION THE |
| | WALL IS NO LONGER ON A 45. PLEASE REVISE |
| | HANGER. |
| | |
| | 10) THE UPLIFT VALUES FOR THE TRUSSES ON |
| | A6 FOR THE REVISION HAVE HIGHER VALUES |
| | DUE TO THE DIFFERENT DESIGN CRITERIA |
| | THAT WAS USED. PLEASE CORRECT. |
| | |
| | 11) THE UPLIFT VALUES FOR THE GIRDER |
| | TRUSS AT THE MASTER BEDROOM ARE SHOWN ON |
| | THE WRONG TRUSS. |
| | |
| | 12)THE PA 28 ANCHORS INDICATED IN DETAIL |
| | 11 ON A5 IS NOT DESIGNED TO BE USED AS A |
| | TRUSS ANCHOR WHERE RESISTANCE TO LATERAL |
| | FORCES IS REQUIRED. PLEASE REVIEW. |
| | |
| | ADDITIONAL FEES WILL BE REQUIRED FOR |
| | ADDITIONAL AREA. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)659-8096 EXT.8202 |