Plan Review Notes
Plan Review Notes For Permit 01080862
Permit Number 01080862
Review Stop B
Sequence Number 1
Notes
Date Text
2001-10-02 00:00:00BUILDING PLAN REVIEW
 PRMIT # 01080862
 5809 CHURCHILL
 O/B FUENTES ORALIA
  
 SBC= 1997 STANDARD BUILDING CODE
  
 1)- SBC 3401.2.2.1 CHANGE OF OCCUPANCY:
 IF THE OCCUPANCY CLASSIFICATION OF ANY
 EXISTING BUILDING OR STRUCTURE IS
 CHANGED, THE BUILDING, ELECTRICAL, GAS,
 MECHANICAL AND PLUMBING SYSTEMS SHALL BE
 MADE TO CONFORM TO THE REQUIREMENTS OF
 THE TECHNICAL CODES FOR NEW CONSRUCTION.
  
 2)-THIS BUILDING WAS ORIGINALLY A STOR-
 AGE SHED, TO CONVERT IT TO A RESIDETIAL
 UNIT PLAANS WILL NEED TO BE DRAWN THAT
 COMPLY WITH THE 1997 STANDARD BUILDING
 CODE OR SBC SSTD-1099 STANDARD FOR HURRI
 CANE RESISTANT RESIDENTIAL CONSTRUCTION.
 PLANS ARE TO DEPICT THE FOUNDATION, AN-
 CHORING SYSTEM,STRAPPING THROUGHOUT,
 FROM FOUNDATION TO THE RAFTERS.
 INDICATE THE COMPLETE SUB PERMIT SYSTEMS
 ELEC,PLUMBING & MECHANICAL, ENERGY CALCU
 LATIONS, SINCE THIS IS A CHANGE OF OCCUP
 ANCY, INDICATE HOW YOU WILL MEET THE RE-
 QUIREMENTS FOR LARGE MISSLE IMPACT RESIS
 TANCE FOR GLAZED OPENINGS.
  
 ONCE PLANS ARE APPROVED YOU WILL NEED TO
 TAKE THE PLANS TO THE COUNTY BUILDING
 DEPARTMENT TO BE ASSESSED FOR IMPACT
 FEES.
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 X 8412