| 2001-10-02 00:00:00 | BUILDING PLAN REVIEW |
| | PRMIT # 01080862 |
| | 5809 CHURCHILL |
| | O/B FUENTES ORALIA |
| | |
| | SBC= 1997 STANDARD BUILDING CODE |
| | |
| | 1)- SBC 3401.2.2.1 CHANGE OF OCCUPANCY: |
| | IF THE OCCUPANCY CLASSIFICATION OF ANY |
| | EXISTING BUILDING OR STRUCTURE IS |
| | CHANGED, THE BUILDING, ELECTRICAL, GAS, |
| | MECHANICAL AND PLUMBING SYSTEMS SHALL BE |
| | MADE TO CONFORM TO THE REQUIREMENTS OF |
| | THE TECHNICAL CODES FOR NEW CONSRUCTION. |
| | |
| | 2)-THIS BUILDING WAS ORIGINALLY A STOR- |
| | AGE SHED, TO CONVERT IT TO A RESIDETIAL |
| | UNIT PLAANS WILL NEED TO BE DRAWN THAT |
| | COMPLY WITH THE 1997 STANDARD BUILDING |
| | CODE OR SBC SSTD-1099 STANDARD FOR HURRI |
| | CANE RESISTANT RESIDENTIAL CONSTRUCTION. |
| | PLANS ARE TO DEPICT THE FOUNDATION, AN- |
| | CHORING SYSTEM,STRAPPING THROUGHOUT, |
| | FROM FOUNDATION TO THE RAFTERS. |
| | INDICATE THE COMPLETE SUB PERMIT SYSTEMS |
| | ELEC,PLUMBING & MECHANICAL, ENERGY CALCU |
| | LATIONS, SINCE THIS IS A CHANGE OF OCCUP |
| | ANCY, INDICATE HOW YOU WILL MEET THE RE- |
| | QUIREMENTS FOR LARGE MISSLE IMPACT RESIS |
| | TANCE FOR GLAZED OPENINGS. |
| | |
| | ONCE PLANS ARE APPROVED YOU WILL NEED TO |
| | TAKE THE PLANS TO THE COUNTY BUILDING |
| | DEPARTMENT TO BE ASSESSED FOR IMPACT |
| | FEES. |
| | |
| | BUILDING PLAN REVIEW |
| | JIM WITMER |
| | (561) 659-8096 X 8412 |