| Date |
Text |
| 2002-01-03 00:00:00 | *************BUILDING UNSAT************* |
| | |
| | 1) IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| | |
| | 2) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 3) INDICATE ON PLANS THE METHOD OF |
| | OF ATTACHMENT THAT WILL BE USED TO |
| | CONNECT THE WOOD FRAME WALLS OF THE |
| | ADDITION TO THE EXISTING STRUCTURE. |
| | |
| | 4) PLEASE CLARIFY IF THE PLANS ARE TO BE |
| | CERTIFIED BY THE ENGINEER (JOHN HOLT) AS |
| | INDICATED BY THE DESIGN CERTIFICATION |
| | FORM THAT YOU SUBMITTED (NEEDS EMBOSSED |
| | SEAL) OR IS BEING DESIGNED TO COMPLY |
| | WITH SSTD 10-97, WHICH DOES NOT REQUIRE |
| | AN ARCHITECT OR ENGINEER. |
| | |
| | 5) PROVIDE ENERGY CALCULATIONS FOR THE |
| | NEW ADDITION AS REQUIRED BY THE 1997 |
| | FLORIDA ENERGY EFFICIENCY CODE SEC. |
| | 101.2.2 AND 101.5.3. |
| | |
| | 6) NOTES FOR GARAGE INDICATE 4:12 ROOF |
| | PITCH AND DRAWINGS INDICATE 3:12 PITCH. |
| | PLEASE CORRECT. |
| | |
| | 7) ROOF SHEATHING IS REQUIRED TO BE |
| | NAILED 4" O.C. AT EDGES AND 6" O.C. |
| | INTERMEDIATE WITHIN 5' OF ROOF EDGE |
| | INCLUDING 1' OVERHANG AT GABLE ENDS |
| | (ZONE 3). CITY OF WPB AMENDMENTS TO |
| | 97 SBC SEC. 2306. |
| | |
| | 8) INDICATE ATTIC ACCESS FOR ADDITION |
| | AND GARAGE. 97 SBC 2309.6 |
| | |
| | 9) INDICATE THE TYPE AND SIZE OF THE TWO |
| | WINDOWS IN THE FLORIDA ROOM. |
| | |
| | 10) PROVIDE ADDITIONAL COPIES OF ALL |
| | PRODUCT APPROVALS THAT WERE SUBMITTED. |
| | TWO COPIES ARE REQUIRED. |
| | |
| | 11)PROVIDE (2) PRODUCT APPROVALS, KEY |
| | PLANS AND INSTALLATION SCHEDULES |
| | INDICATING THE SPECIFIC TYPES OF ANCHORS |
| | TO BE USED FOR STORM PANELS. REQUIRED |
| | FOR ALL EXTERIOR GLAZED OPENINGS ON |
| | NEW ADDITION AND GARAGE. |
| | |
| | 12) PROVIDE TWO LEGIBLE COPIES OF SURVEY |
| | INDICATING THE FRONT, REAR AND SIDE |
| | SET BACKS TO THE ADDITION AND THE |
| | DETACHED GARAGE. |
| | |
| | 13) THE BOTTOM OF THE FOOTING SHALL BE |
| | A MINIMUM OF 12" BELOW FINISH GRADE, AND |
| | AN APPROVED STUCCO STOP PLACED NOT LESS |
| | THAN 6" ABOVE FINISH GRADE IS REQUIRED |
| | TO TERMINATE THE STUCCO AT THE BASE OF |
| | THE WALL. PLEASE INDICATE THESE ITEMS ON |
| | THE PLANS. |
| | |
| | IF YOU HAVE QUESTIONS PLEASE CALL: |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)659-8096 EXT.8202 |