Plan Review Notes
Plan Review Notes For Permit 01070604
Permit Number 01070604
Review Stop R
Sequence Number 3
Notes
Date Text
2001-10-30 00:00:00TRUSSES
 UNSAT
  
 1) FOR TRUSS S13 THE TRUSS DRAWINGS
 INDICATE AN UPLIFT OF 1600# AT JOINT 13.
 SHEET A-3 OF THE PLANS INDICATE AN HC10
 CONNECTOR RATED FOR 1325# OF UPLIFT.
  
 2) FOR TRUSS S14 THE TRUSS DRAWINGS
 INDICATE AN UPLIFT OF 1650# AT JOINT 13.
 SHEET A-3 OF THE PLANS INDICATE AN HC10
 CONNECTOR RATED FOR 1325# OF UPLIFT.
  
 3) FOR TRUSS SG2 THE TRUSS DRAWINGS
 INDICATE 1860# OF UPLIFT AT JOINT 21 AND
 THE PLANS INDICATE A HETAL-16 RATED FOR
 1365# OF UPLIFT.
 THE TRUSS DRAWINGS INDICATE 4200# UPLIFT
 AT JOINT 15 AND PLANS HAVE LSTA-24 RATED
 FOR 1295# OF UPLIFT.
  
 PLEASE REVIEW AND CORRECT.
  
 THESE COMMENTS APPLY TO THE TRUSSES FOR
 PERMIT NUMBERS 01070611, 01070616 AND
 01071305.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202