| Plan Review Notes For Permit 01061269 |
| Permit Number |
01061269 |
|
| Review Stop |
R |
| Sequence Number |
3 |
|
| Notes |
| Date |
Text |
| 2001-12-14 00:00:00 | REVISION CHECKLIST: | | | 1-WINDOWS AT BEDROOM #1 DON'T COMPLY | | | WITH SECTION 1005.4SBC 1997 FOR | | | EGRESS REQUIREMENTS. MINIMUM CLEAR | | | WIDTH AND MINIMUM TOTAL CLEAR OPENING. | | | *PROVIDE CUT SHEETS FOR CASEMENT | | | WINDOWS TO BE USED TO ASSURE COMPLIAN- | | | CE WITH MINIMUM SIZES REQUIRED. | | | 2-SPECIFY ON PLANS AREAS TO HAVE SAFETY | | | GLASS AS REQUIRED BY SEC. 2405.2 SBC. | | | SEE PLANS FOR COMMENTS. | | | 3-REVISE ELECTRICAL AND PLUMBING PLANS | | | AS REQUIRED TO MATCH REVISION. | | | 4-PROVIDE COMPLETE DETAILS AND SPECS | | | FOR ACCORDION LOUVERED PANEL ENCLOSURE | | | AT LOGGIA. SEC. 1606 SBC 1997 AND | | | SEC. 104.2.2 CITY AMENDMENTS TO SBC/97 | | | 5-PROVIDE ALL INFORMATION REQUIRED ON | | | PROVISO DATED 9-10-01 TO AVOID ANY | | | DELAYS OR CONFLICTS. |
|