2001-07-10 00:00:00PROVIDE THE TEST REPORT FOR THE WATER
 CURTAIN AT THE GLASS DOOR.
  
 NOTE 11 ON G2 RE PLANTONS FOR DOORS
 MUST COMPLY WITH NFPA 80
  
 NOTE 22, G2 RE UNDERCUT OF DOORS MUST
 COMPLY WITH NFPA 80 FOR ANY FIRE RATED
 DOORS.
  
 A LIFE SAFETY PLAN MUST ACCOMPANY THE
 PERMIT FOR THE TEMPORARY DEMISING OF
 THEFLOOR PLAN SHOWN ON SHEET D1.TWO
 INDEPENDENT MEANS OF EGRESS MUST BE
 MAINTAINED.SBC 1004.2.2
  
 DOOR #123D AT THE ELEVATOR LOBBY IS
 REQUIRED TO BE 20 MINUTE FIRE RATED.
 SEE SBC 412.6.1.
  
 PROVIDE THE HC ACCESSIBILTY TO THE
 TOILET ROOMS AND DRINKING FOUNTAINS AS
 REQUIRED BY FCBC 4.1.6. (2) (A)(III)
 AND (V)