2001-07-11 00:00:00BUILDING PLAN REVIEW
 PERMIT # 01060951
 700 S ROSEMARY AVE # 106
 CONT: DITOCCO KONSTRUCTION INC
 P: (954) 943-7708
 ARCH: EDMOND LE BANC
 P: (561) 585-3403
  
 SBC= STANDARD BUILDING CODE
 SBC*= AMENDMENTS/ STANDARD BUILDING CODE
 1)- SBC* 104.2.2- WE WILL NEED TO KNOW
 THE OCCUPANCIES THAT ARE TO OCCUPY THE
 SECOND FLOOR, WE UNDERSTAND THAT THE
 TENANT SPACE 202-B4.C MAY BE A NIGHTCLUB
 AND THE TENANT SPACE 202 B4.BMAY BE SOME
 TYPE OF GYM.
  
 2)- TENANT SPACE 202 B4.B (4936 SQ FT)
 WILL REQUIRE (2) MEANS OF EGRESS,
 SBC 1004.2.1. 2 APPROVED INDEPENDANT
 EXITS, ACCESSIBLE TOEACH TENANT AREA
 SERVING EVERY STORY. THE MAIN STAIRWAY
 WOULD HAVE TO COMPLY WITH RATINGS FOR
 MINIMUM FIRE RESISTANCE (TABLE 705.1.2)
 FOR SHAFT ENCLOSURES. 1 HR FOR BUSINESS
 & MERCANTILE. 2HR. SHAFT RATING (NOTE 2)
 FOR ASSEMBLY, FIRST & SECOND FLOOR.SBC
 1006.1 ENCLOSED STAIRWAYS.705.2/T705.1.2
 3)- TENANT SPACE 202 B4.C THIS SPACE IF
 OCCUPIED BY AN ASSEMBLY OCCUPANCY WOULD
 ALSO REQUIRE A 2 HR TENANT SEPERATION AS
 NOTED ON THE PLANS. SBC 1019.1: THE
 MINIMUM AGGREATE WIDTH OF MAIN ENTRANCE
 DOORWAYS FOR GROUP A ASSEMBLY OCCUPANC-
 IES SHALL BE SUFFICIENT TO ACCOMODATE
 50% OF THE OCCUPANT LOAD. EACH LEVEL OF
 A, ASSEMBLY OCUPANCY SHALL HAVE ACCESS
 TO A MAIN EXIT AND SHALL BE PROVIDED
 WITH ADDITIONAL EXITS OF SUFFICIENT
 WIDTH TO ACCONIDATE 1/2 OF THE TOTAL
 OCCUPANT LOAD SERVED BY THAT LEVEL.
  
 THIS WOULD REQUIRE THE FRONT STAIRWAY TO
 HAVE A 2 HR RATING, 1 1/2 HR RATING ON
 OPENINGS WHICH IS MISSING ON THE EXIST-
 ING STAIRWELL DOOR.
  
 THERE SEEMS TO BE A PROBLEM WITH EXITING
 FOR THIS TENANT SPACE, UNDER ASSEMBLY
 OCCUPANCY. WHEN WE USE 15 SQ FT/ PERSON
 THERE IS A GREAT CONCERN IF THE STAIRS
 & DOORWAYS WILL HANDLE THE LOADING
 PLEASE SUBMITT A LIFE SAFETY PLAN FOR
 THE FIRST FLOOR & SECOND FLOOR SHOWING
 THE EXITING, THE REAL PROBLEM!!!! IS
 WHEN UNDER A NIGHTCLUB OCCUPANCY WE GO
 A MORE CONCENTRATED AREAS FOR DANCE
 FLOORS TO 7 SQ FT & 3 SQ FT FOR BARS.
 THE DESIGN DOESN'T BEGIN TO WORK FOR
 A CONSINTRATION AS THIS MAY BE.
  
 4)- SBC 1003.3.5 THE LIFE SAFETY PLAN
 NEEDS TO SHOW THE CONVERGING EXITS AND
 THE TENANT LOADS THROUGH TO THE EXTERIOR
 OF THE BUILDING.
  
 5)- SBC 104.2.2* ADDITIONAL INFORMATION
 SERVICE CORRIDOR 108: VERIFY THAT THERE
 IS A ACCESSIBLE RAMP WITH A HEIGTH TRANS
 ITION OF 1'-4"?
  
 BUILDING PLAN REVIEW
 JIM WITMER
 (561) 659-8096 EX 8412