| Plan Review Notes For Permit 01060446 |
| Permit Number |
01060446 |
|
| Review Stop |
B |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-07-11 00:00:00 | BUILDING PLAN REVIEW | | | 01060446 | | | 1000 S DIXIE HWY | | | CONT: FINROCK CONST | | | P: (407) 293-4000 | | | | | | 1)- STRUCTURAL SHEET S101: FOOTING | | | SCHEDULE- THE TOP OF THE EXTERIOR | | | FOUNDATION AS PROPOSED IN THE FOOTING | | | SCHEDULE HAS A DISCREPANCY WITH THE | | | RECOMMANDATIONS PROPOSED BY ARDAMAN & | | | ASSOCIATES IN THEIR SOILS REPORT. THE | | | FOOTING SCHEDULE HAS THE TOP OF FOOTINGS | | | AT EXTERIOR FOUNDATION AT 13'-3 1/2" AS | | | THE SOILS REPORT REQUEST THAT THESE | | | EXTERIOR FOUNDATIONS BE 18" BELOW THE | | | ADJACENT OUTSIDE FINAL GRADE, THIS WOULD | | | PUT THEM AT ELEVATION 12'-0" TO 12'-3" | | | TO THE TOP OF FOUNDATION. | | | | | | PLAN REVIEW | | | JIM WITMER | | | (561) 659-8096 EX 8412 |
|