Plan Review Notes
Plan Review Notes For Permit 01051593
Permit Number 01051593
Review Stop P
Sequence Number 7
Notes
Date Text
2002-05-16 00:00:00DENIED
 REFERENCE: SPC-94 - SGC-97 - FACBC-97
  
 1) FROM PREVIOUS REVIEWS, SHTS P1/P2
 BAR AREA 3 COMPARTMENT SINK SHALL DRAIN
 INDIRECTLY INTO A FLOOR SINK. FLOOR SINK
 UNDER ICE BIN SHALL NOT HAVE FUNNEL AS
 SHOWN ON RISER DIAGRAM.
 2) SHT P-1 FLOOR SINK TO BE UNDER FIX-
 TURE AT ICE BINS. PLEASE SHOW PIPING ON
 FLAT DRAWING FOR FLOOR SINK AND HAND
 SINK AS REQUIETED IN LAST TWO REVIEWS.
 3RD REQUEST.
 3) SHTS P1/P2 RISER DIAGRAM AND FLOOR
 PLAN STILL DO NOT MATCH. LAVS AND FLOOR
 DRAIN SHALL COME OFF BLDG DRAIN ON RISER
 DIAGRAM THE SAME AS ON THE FLOOR PLAN.
 3RD REQUEST.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377