Plan Review Notes
Plan Review Notes For Permit 01051593
Permit Number 01051593
Review Stop P
Sequence Number 6
Notes
Date Text
2002-04-24 00:00:00DENIED
 REFERENCE: SPC-94 - SGC-97 - FACBC-97
  
 1) FROM PREVIOUS REVIEW, SHTS P-1/P-2
 BAR AREA 3 COMPARTMENT SINK STILL DRAINS
 INTO THE FLOOR DRAIN. FLOOR SINK UNDER
 ICE BIN IS A SAFE WASTE WHICH IS NOT
 APPROVED. DOUBLE TRAPING IS NOT ALLOWED.
 VENT FLOOR SINKS PROPERLY.
 2) SHT P-1 FLOOR SINK TO BE UNDER FIX-
 TURE AT ICE BINS. PLEASE SHOW PIPING ON
 FLAT DRAWING FOR FLOOR SINK AND HAND
 SINK AS REQUESTED IN LAST REVIEW. 2ND
 REQUEST.
 3) SHTS P-1/P-2 RISER DIAGRAM AND FLOOR
 PLAN STILL DO NOT MATCH. LAVS AND FLOOR
 DRAIN SHALL COME BLDG DRAIN ON RISER
 DIAGRAM THE SAME AS ON THE FLOOR PLAN.
 THIS COMMENT FROM LAST REVIEW. SEE RED
 LINE MARKS ON PLANS.
  
 REVIEW BY KEN STEVENS
 (561) 659-8096 EXT 8377