| Plan Review Notes For Permit 01051593 |
| Permit Number |
01051593 |
|
| Review Stop |
M |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2001-07-09 00:00:00 | *******************DENIED*************** | | | | | | | | | ADDITIONAL PERMITS REQUIRED FOR HOOD, | | | FIRE SUPRESSION AND WALK-IN COOLERS. | | | PLEASE PROVIDE PLANS WITH MANUFACTURER | | | SUBMITTAL DATA WITH PERMIT APPLICATIONS. | | | | | | PROVIDE LOCATION OF THE FLUE PIPE FOR | | | GAS WATER HEATER. | | | | | | SUPPLY DUCT TO STORAGE ROOM APPEARS TO | | | PENETRATE A RATED WALL, FIRE DAMPER IS | | | REQUIRED.PLEASE PROVIDE MANUFACTURER | | | DETAILS FOR COMPLIANCE WITH 1997 SMC | | | 610.1.2.LOCATIONS OF FIRE DAMPERS | | | NEEDTO BE INDICATED ON PLAN. | | | | | | NOTE:NO COMBUSTIBLES ABOVE THE CEILING | | | IN THE RETURN AIR PLENUM. | | | | | | IF YOU HAVE ANY QUESTIONS PLEASE CONTACT | | | PATTY KRAUSS 659-8096 EXT. 8338. |
|