Plan Review Notes
Plan Review Notes For Permit 01051470
Permit Number 01051470
Review Stop R
Sequence Number 2
Notes
Date Text
2001-09-10 00:00:00CHECKLIST:
 1-ENTRY DOOR SIZE DOESN'T PROVIDE THE
 MINIMUM CLEAR OPENING (AT LEAST ONE
 LEAF) OF 32" AS REQUIRED BY TABLE
 1004 SBC 1997.
 2-COMPLETE THE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM.
 3-PROVIDE SMOKE DETECTORS AT EACH STORY
 AS REQUIRED BY SEC. 905.2 SBC 1997.
 4-ENTRY DOOR ASSEMBLY, FRENCH DOORS WITH
 SIDELITES AND BAY WINDOWS CALL FOR
 2XSTRUCTURAL MULLIONS, BUT THERE IS
 NOT SPECIFICATIONS FOR FASTENERS.
 REMEMBER THAT THIS ASSEMBLIES WILL
 HAVE MISSILE IMPACT GLAZING.
 5-ENGINEER OF RECORD TO REVIEW ALL
 MISSILE IMPACT PRODUCT APPROVALS TO
 VERIFY THAT THEY WILL MEET THE DESIGN
 PRESSURES CALCULATED ON PLANS.
 6-PROVIDE PRODUCT APPROVALS FOR:
 -INSWING FRENCH DOORS AS SHOWN ON PLANS
 -EXTERIOR SWING DOORS. EG @ LAUNDRY,ETC
 -UL LISTING FOR BBQ.
 7-OWES ADDITIONAL FEES OF $1234.68 FOR
 LOW VALUATION AND RADON FEES. SEE
 ATTACHED RECEIPT.