| Date |
Text |
| 2001-07-17 00:00:00 | CHECKLIST: |
| | 1-PAY IMPACT FEES TO PALM BEACH COUNTY. |
| | BRING STAMPED DRAWINGS AND RECEIPT. |
| | 2-NEED TO FILE NOTICE OF COMMENCEMENT. |
| | 3-PROVIDE SIGNED, SEALED AND DATED |
| | SURVEY WITH NEW BUILDING LAYOUT AND |
| | PROPOSED FINISH FLOOR ELEVATIONS. |
| | 4-COMPLETE THE DESIGN CERTIFICATION FOR |
| | BUILDING CODE COMPLIANCE FORM ATTACHED |
| | 5-SPECIFY DESIGN PRESSURES CALCULATED AT |
| | ALL EXTERIOR OPENINGS. SEC 1606 SBC/97 |
| | 6-ENTRY DOOR TO HAVE 32" MINIMUM CLEAR |
| | OPENING (AT LEAST ON ONE LEAF) AS |
| | REQUIRED BY TABLE 1004 SBC 1997. |
| | 7-PROVIDE COMPLETE AREA TABULATIONS. EG: |
| | A/C AREAS, PORCHES, GARAGE, BALCONIES. |
| | 8-WINDOWS SPECIFIED DON'T PROVIDE THE |
| | MIN CLEAR OPENINGS REQUIRED FOR EGRESS |
| | SEC. 1005.4 SBC 1997. REVISE SIZE OF |
| | WINDOWS AT GUEST BEDRM AND 2ND FLOOR |
| | BEDRMS. ALSO, OFFICE AT 2ND FLOOR MAY |
| | BE CONSIDERED AS A BEDRM, THEREFORE, |
| | WINDOWS SHALL COMPLY W/ THIS SEC. TOO. |
| | 9-PROVIDE ATTIC ACCESS AT GARAGE, LOGGIA |
| | & MASTER BEDRM BALCONY. SEC 2309.6 SBC |
| | 10-PROVIDE SMOKE DETECTORS AT EACH STORY |
| | AS REQUIRED BY SEC. 905.2 SBC 1997. |
| | 11-FLAT ROOF AND PARAPETS: |
| | A)MIN SLOPE 1/4"/FT. SEC 1503.1.2.3 SBC |
| | B)PROVIDE DRAINAGE FOR MASTER BEDROOM |
| | BALCONIES AND EMERGENCY SCUPPERS AS |
| | REQUIRED BY SEC. 1517.6.4 SBC 1997. |
| | 12-SPECIFY ATTIC VENTILATION AS REQUIRED |
| | BY SEC 2309.7 SBC 1997. |
| | 13-ARCHITECT TO DATE DRAWINGS AT TIME OF |
| | SEALING. CHAPTER 481 FLORIDA STATUTES |
| | 14-REVISE DESIGN ASSUMPTION NOTES ON |
| | SHEET S-1.1. ASCE 7-95 FOR 145MPH OR |
| | SBC FOR 110 MPH. |
| | 15-OWNER TO SIGN & DATE ENERGY CALCS. |
| | 16-SOIL TEST REPORT TO HAVE ORIGINAL |
| | SIGNATURE, DATE AND EMBOSSED SEAL AS |
| | REQUIRED BY CHAPTER 471 FL. STATUTES. |
| | 17-PROVIDE PRODUCT APPROVAL FOR: |
| | A)ENTRY DOOR WITH SIDELITES AND TRANSOM |
| | SINGLE ASSEMBLY AS SHOWN ON PLANS. |
| | B)FIXED WINDOWS(NEED APPROVED DWGS) |
| | C)FRENCH DOORS WITH SIDELITES SINGLE |
| | ASSEMBLY AS SHOWN ON PLANS. |
| | D)SWING DOORS. EG: @ LAUNDRY AND BATH. |
| | E)UL LISTING AND SPECS FOR FIREPLACE. |
| | F)UL LISTING AND SPECS FOR BBQ. |
| | G)ROOF TILE. |
| | H)FLAT ROOF SYSTEM. |
| | I)WINDOW MULLIONS. |
| | |
| | 18-SEE PLANS FOR ADDITIONAL MINOR |
| | COMMENTS AND PLEASE RETURN REVIEWED |
| | SET IN ORDER TO EXPEDITE THE REVIEW |
| | PROCESS. |