2001-06-23 00:00:00*************BUILDING UNSAT*************
  
 1) IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, PLANS STAMPED BY THEM AND
 COPY OF RECEIPT SUBMITTED TO CITY OF
 WEST PALM BEACH BUILDING DEPARTMENT,
 BEFORE A BUILDING PERMIT CAN BE ISSUED.
 SBC 104.2.2
  
 2) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT MUST BE SUBMITTED BEFORE A
 PERMIT CAN BE ISSUED.
  
 3) SHEET C1 INCORRECTLY SITES 1999 SBC
 AND 1999 FLORIDA ENERGY CODE. THE CITY
 OF WPB CURRENTLY USES THE 1997 SBC AND
 THE 1997 FLORIDA ENERGY CODE
 REQUIREMENTS. PLEASE CORRECT ON YOUR
 MASTER.
  
 4)RIGHT ELEVATION EXCEEDS THE
 PERCENTAGEOF WALL OPENINGS PERMITTED BY
 TABLE 600 OF THE 97 SBC. TWENTY PERCENT
 OF WALL
 AREA IS ALLOWED AS WALL OPENINGS FOR A
 HORIZONTAL SEPARATION OF EIGHT FEET.
 PLEASE REVIEW AND CORRECT.
  
 5) PROVIDE ATTIC ACCESS PER 97SBC 2309.6
  
 6) SHEET A-2 IS NOT SIGNED BY DESIGN
 PROFESSIONAL IN ONE SET OF PLANS.
  
 7) MEAN ROOF HEIGHT (DISTANCE FROM
 FINISH GRADE TO AVERAGE HEIGHT OF
 TALLEST ROOF) APPEARS TO BE 18 FT., NOT
 15 FT. PLEASE REVIEW AND CORRECT. DESIGN
 CERTIFICATION FORM WILL HAVE TO BE
 CORRECTED,AS BASIC VELOCITY PRESSURE
 WILL CHANGE.
  
 8) PLEASE REVIEW DETAIL 5/A5 CONNECTION
 FOR GIRDER TRUSS AT REAR COVERED PATIO.
 IT DOES NOT CORRESPOND TO PLAN.
  
 9) PLEASE INDICATE CONNECTORS FOR TRUSS
 TO GIRDER ATTACHMENT AT LIVING ROOM.
 SEE SHEET A-6.
  
 ROBERT MCDOUGAL
 BLDG. PLAN REVIEW
 (561)659-8096 EXT.8202