Plan Review Notes
Plan Review Notes For Permit 01051384
Permit Number 01051384
Review Stop R
Sequence Number 1
Notes
Date Text
2001-07-03 00:00:00CHECKLIST:
 1-PLEASE FILE NOTICE OF COMMENCEMENT.
 2-PLEASE PAY IMPACT FEES TO PALM BCH CO.
 3-UPDATE SHEET C-1. SEE COMMENTS.
 4-SHEET A-1 IS MISSING SPECIFICATIONS
 FOR CONCRETE SLAB.
 5-PROVIDE ATTIC ACCESS. SECTION 2309.6
 SBC 1997.
 6-REVISE THE DESIGN CERTIFICATION FOR
 BUILDING CODE COMPLIANCE FORM. THE
 MEAN ROOF HEIGHT IS INCORRECT (18'-6"
 +/- ). REVISE VELOCITY PRESSURE
 ACCORDINGLY. TABLE 1606.2A SBC 1997.
 7-SOIL TEST REPORT TO HAVE ORIGINAL SEAL
 SIGNATURE AND DATE. CHAPTER 471 FL. ST
 8-PROVIDE PRODUCT APPROVAL FOR:
 A)GLASS BLOCK DRAWINGS ARE NOT LEGIBLE.
 B)SLIDING GLASS DOOR WITH TRANSOM ABOVE
 SINGLE ASSEMBLY AS SHOWN ON PLANS.
 C)WINDOW MULLIONS.
 D)FIXED WINDOWS WITH SIZES AS SHOWN ON
 ARCHITECT'S PLANS.
 E)PGT ENGINEER TO SIGN, SEAL AND DATE
 LETTER FOR SHAPED FIXED WINDOWS AS
 REQUIRED BY CHAPTER 471 FL STATUTES.
 F)ENTRY DOORS DRAWINGS ARE NOT LEGIBLE.
 9-STORM PANELS:
 -CLEARLY INDICATE ON APPROVED DRAWINGS
 THE SPECIFIC MOUNTING CONDITIONS AND
 ANCHOR TO BE USED ACCORDING TO THE
 MEAN ROOF HEIGHT, DESIGN PRESSURES,
 EDGE DISTANCE, PANEL SPAN, CONNECTION
 TYPE AND STRUCTURE TO BE ATTACHED TO
 (NOTE: THIS STRUCTURE IS MASONRY, NOT
 CONCRETE).
 -REVISE INSTALLATION SCHEDULE ANCHOR
 SPACING TO REFLECT CONDITIONS ABOVE.
 10-PROVIDE SURVEY WITH ORIGINAL SEAL,
 SIGNATURE AND DATE.