| 2001-07-03 00:00:00 | *************BUILDING UNSAT************* | | | | | | LEA SMITH, BLDG. PLANS EXAMINER | | | 659-8096 EXT 8394 | | | | | | | | | 1. PROVIDE FLOOD ZONE ELEVATION | | | CERTIFICATE FOR NEW CONSTRUTION WITH | | | BFEBEFORE C/O. | | | | | | 2. PROVIDE 2 CURRENT COMPLETE COPIES OF | | | SBCCI OR METRO DADE PRODUCT APPROVALS | | | FOR: | | | SINGLE FRENCH DOORS (SUBMITTED | | | APPROVALS EXPIRED 4/2/01) | | | | | | 3. DETAIL A/3 ON SHEET 3B: REBENDING OF | | | FLANGE ON GIRDER HANGER IS NOT ALLOWED | | | PER MFGR.CAPACITY OF HANGER NEEDS TO | | | BE DERATED.PLEASE CORRECT. | | | | | | 4. DESIGN PARAMETERS ON SHEET 1 LISTS | | | 26 PSF & MEAN ROOF HEIGHT AS 17'. | | | PLEASECORRECT AS PER PLAN. | | | | | | 5. INDICATE ON GLASS BLOCK SUBMITTALS | | | WHICH TYPE BEING USED. | | | | | | PLEASE RESUBMIT WHEN ABOVE CORRECTIONS | | | ARE COMPLETED. |
|