Plan Review Notes
Plan Review Notes For Permit 01051202
Permit Number 01051202
Review Stop P
Sequence Number 1
Notes
Date Text
2001-06-07 00:00:00PLUMBING PLAN REVIEW"DENIED"
 ROSARIAN ACADEMY MONTESSORI CLASSROOMS
 (1) SHT A2 REST RM'S IN CLASS RM TO
 COMPLY W/FACBC-97 SEC 4.22.1 AND SPC 94
 TAB 407 MINIMUM FACILITIES, ONLY 1 W/C
 FOR 1-50 PERSONS, IS REQUIRED.
 (2) SHT A2 BREAK RM SINK IN STAFF LOUNGE
 TO COMPLY W/FACBC 97 SEC 4.24 HGTH 34",
 AND SEC 4.24.5 CLEAR FLR SPACE 30"X48".
 (3) SHT P1,P2 AIR CHAMBER,GENERAL NOTE
 #16 COMPLY WSPC 94 SEC 607.8.3 AIR CHAM-
 BERS TO BE ACCESSIBLE, RECHARGEABLE.
 (4) SHT P1 WATER PIPE ISOMETRIC,SHOW
 WHICH LINE IS HOT AND WHICH IS COLD,WITH
 DASHED LINES.SPC 94 SEC 104.3
 END OF COMMENTSPAUL SCHMITZ
 QUESTIONS561-659-8096X 8233
 PREVIOUS PHONE CONVERSATION WITH
 MR. HAMED RODREGREQUEZ832-5599