| Plan Review Notes For Permit 01051020 |
| Permit Number |
01051020 |
|
| Review Stop |
R |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2001-07-20 00:00:00 | *************BUILDING UNSAT************* | | | | | | 1) THE SECOND STORY WINDOW ON THE RIGHT | | | SIDE OF THE STRUCTURE AT THE STAIR | | | LANDING IS LOCATED IN A WALL ON A ZERO | | | LOT LINE. NO OPENINGS ARE ALLOWED IN THE | | | WALL PER TABLE 600 OF THE 97 SBC. PLEASE | | | CORRECT THE DRAWINGS. | | | | | | 2) THE PRIVACY WALL FOOTING SHOWN IN | | | DETAIL 1 ON SHEET S-1 (ZERO LOT LINE), | | | ENCROACHES ON THE ADJACENT PROPERTY AND | | | MAY INTERFERE WITH THE ADJOINING | | | STRUCTURE. | | | | | | 3) THE IMPORTANCE FACTOR LISTED IN THE | | | DESIGN CERTIFICATION FORM ON SHEET S-1 | | | IS INCORRECT. THE CORRECT IMPORTANCE | | | FACTOR FROM TABLE 6-2 IN ASCE 7-95 IS | | | 1.00. | | | | | | ROBERT MCDOUGAL | | | BLDG. PLAN REVIEW | | | (561)659-8096 EXT.8202 |
|