| Date |
Text |
| 2001-06-14 00:00:00 | *************BUILDING UNSAT************* |
| | |
| | 1) IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| | |
| | 2) TABLE 600: NO OPENINGS ARE ALLOWED |
| | IN A ZERO LOT LINE WALL. A PORTION OF |
| | THE LIVING ROOM WINDOW SHOWN ON SHEET |
| | A-1.0 AS A DOUBLE WINDOW AND ON A-2.0 AS |
| | A SINGLE WINDOW IS LOCATED IN THE ZERO |
| | LOT LINE WALL AND IS NOT ALLOWED. THE |
| | WINDOW LOCATED ON THE SECOND FLOOR AT |
| | THE STAIR LANDING IS ALSO LOCATED IN THE |
| | ZERO LOT LINE WALL. PLEASE MAKE THE |
| | REQUIRED CORRECTIONS. |
| | |
| | 3) THE A/C COMPRESSOR UNIT SHOWN ON THE |
| | FIRST FLOOR PLAN (A-1.0) IS LOCATED ON |
| | THE ADJACENT LOT. PLEASE CORRECT. |
| | |
| | 4) FIRST FLOOR PLAN (A-1.0) APPEARS TO |
| | INDICATE A PRIVACY WALL AT THE COVERED |
| | PORCH,HOWEVER NOTHING IS INDICATED ON |
| | THE FOUNDATION PLAN (S-1).PLEASE CLARIFY |
| | |
| | 5) PAGE 5 OF THE SOIL REPORT STATES THAT |
| | EXTERIOR FOUNDATIONS SHOULD BEAR AT |
| | LEAST 18" BELOW ADJACENT OUTSIDE FINAL |
| | GRADE. THE CITY AMENDMENTS TO THE 97 SBC |
| | REQUIRE THE BUILDING FLOOR ELEVATION TO |
| | BE A MINIMUM OF 4" ABOVE FINAL GRADE. |
| | THIS EQUATES TO A 22" DEEP EXTERIOR |
| | FOOTING. THE PLANS INDICATE 18" DEEP |
| | FOOTINGS. PLEASE REVIEW AND CORRECT OR |
| | PROVIDE APPROVAL LETTER FROM SOIL |
| | ENGINEER. |
| | |
| | 6) THE PRODUCT APPROVAL FOR THE 16'X7' |
| | OVERHEAD GARAGE DOOR DOES NOT LIST A |
| | DOOR OF THIS SIZE WHICH HAS A DESIGN |
| | LOAD CAPABLE OF WITH STANDING THE DESIGN |
| | PRESSURES (+42,-45) GIVEN ON SHEET S1 |
| | FOR THE GARAGE DOOR OPENING. |
| | |
| | 7)PROVIDE (2) CURRENT AND COMPLETE |
| | COPIES OF SBCCI OR METRO-DADE PRODUCT |
| | APPROVALS FOR: |
| | - ROOFING MATERIALS FOR FLAT ROOF AREAS |
| | |
| | 8) PRODUCT APPROVAL FOR "SKANDIA" ROOF |
| | TILES EXPIRED ON 12-16-00. |
| | |
| | 9) TRUSSES: PROVIDE DETAIL OF ATTACHMENT |
| | OF GIRDER FG1 AT COLUMN MC4(SHEET S1). |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)659-8096 EXT.8202 |