| Plan Review Notes For Permit 01050850 |
| Permit Number |
01050850 |
|
| Review Stop |
P |
| Sequence Number |
2 |
|
| Notes |
| Date |
Text |
| 2001-10-15 00:00:00 | DENIED | | | REFERENCE: SPC-94 - FACBC-97 | | | | | | 1) SPC-94 TABLE 407 REQUIRED 2 BATHROOMS | | | 1 MALE AND 1 FEMALE. | | | | | | 2) DOOR TO RESTROOM SHALL NOT OPEN INTO | | | CLEAR FLOOR SPACE OF DRINKING FOUNTAIN, | | | OR LAV. | | | | | | 3) IRRIGATION ON SEPARATE PERMIT. | | | PLUMBING CONTRACTOR TO INSTALL A SEPAR- | | | ATE TEE WITH A VALVE AND AN N-36 WATTS | | | VACUUM BREAKER TO TIE INTO. | | | | | | 4) TWO WAY CLEAN OUTS ARE REQUIRED FOR | | | EACH BLDG DRAIN WHERE IT TIES INTO THE | | | BLDG SEWER. | | | | | | 5) SHEET E-1, WATER RISER. AIR CHAMBERS | | | ARE "QUICK FIX" WATER HAMMER ARRESTORS | | | SHALL BE INSTALLED PER MANUFACTURE'S | | | INSTALLATION AND WH-PDI 201. PLACE CLOSE | | | TO SOURCE OF SHUTOFF, NOT ON TOP OF DROP | | | AS SHOWN. | | | | | | REVIEW BY KEN STEVENS | | | (561) 569 8096 EXT. 8377 |
|