| Date |
Text |
| 2001-06-08 00:00:00 | *************BUILDING UNSAT************* |
| | |
| | 1)IMPACT FEES MUST BE PAID TO PALM |
| | BEACH COUNTY, PLANS STAMPED BY THEM AND |
| | COPY OF RECEIPT SUBMITTED TO CITY OF |
| | WEST PALM BEACH BUILDING DEPARTMENT, |
| | BEFORE A BUILDING PERMIT CAN BE ISSUED. |
| | SBC 104.2.2 |
| | |
| | 2) A RECORDED COPY OF THE NOTICE OF |
| | COMMENCEMENT MUST BE SUBMITTED BEFORE A |
| | PERMIT CAN BE ISSUED. |
| | |
| | 3)PROVIDE (2) CURRENT AND COMPLETE |
| | COPIES OF SBCCI OR METRO-DADE PRODUCT |
| | APPROVALS FOR: |
| | - WINDOWS |
| | - EXTERIOR DOORS |
| | - GARAGE DOOR |
| | |
| | 4) PROVIDE ATTIC ACCESS PER 1997 SBC SEC |
| | 2309.6. |
| | |
| | 5) PROVIDE (2) PRODUCT APPROVALS, KEY |
| | PLANS AND INSTALLATION SCHEDULES |
| | INDICATING THE SPECIFIC TYPES OF ANCHORS |
| | TO BE USED FOR STORM PANELS. REQUIRED |
| | FOR IMPACT PROTECTION OF GLAZED OPENINGS |
| | |
| | 6) DOOR FROM GARAGE TO CONDITIONED SPACE |
| | MUST COMPLY WITH 97 FLORIDA ENERGY CODE |
| | FOR BUILDING CONSTRUCTION. |
| | |
| | 7) THE TOTAL ROOF LOADS ON PLANS DO NOT |
| | CONCUR. SHEET 4 HAS 55 PSF AND SHEET 8 |
| | HAS 47 PSF. PLEASE REVIEW AND CORRECT. |
| | |
| | 8) THE PLANS SUBMITTED APPEAR TO BE |
| | MISSING SOME PAGES. ONE SET HAS 8 OF 9 |
| | PAGES & ONE SET HAS 7 OF 9. PLEASE |
| | SUBMIT (2) COMPLETE SETS. |
| | |
| | ROBERT MCDOUGAL |
| | BLDG. PLAN REVIEW |
| | (561)659-8096 EXT.8202 |