| Plan Review Notes For Permit 01050173 |
| Permit Number |
01050173 |
|
| Review Stop |
P |
| Sequence Number |
1 |
|
| Notes |
| Date |
Text |
| 2001-05-09 00:00:00 | REVIEW NOTES:PASSED | | | | | | *** PLUMBING NOTES *** | | | | | | PAGE A-1 PLUMBING NOTES #16 AIR CHAMBERS | | | MUST COMPLY WITH SPC-94 607.8.2 AND | | | 607.8.3, MUST BE ACCESSABLE AND RECHARG- | | | ABLE. | | | | | | PAGE A-1 PLUMBING NOTES #19 SPC-94 PIPE | | | 2" AND SMALLER SHALL BE INSTALLED WITH | | | FALL OF 1/4" PER FOOT. 705.2 | | | | | | SPC-94 TABLE 714.1, 3" PIPE (FOOTNOTE-3) | | | NOT MORE THAN 2 W/C'S ALLOWED ON 3" | | | SANITARY. | | | | | | SPC-94 MODEL COUNTYWIDE AMMENDMENTS TO | | | CODE 607.7 "NO MORE THAN 2 FIXTURES | | | SHALL BE SUPPLIED WITH A 1/2" COLD WATER | | | SUPPLY. NO MORE THAN 4 FIXTURES SHALL BE | | | SUPPLIED WITH A 1/2" HOT WATER SUPPLY. | | | | | | REVIEW BY KEN STEVENS (561) 659-8096 | | | EXT. 8377 |
|