Plan Review Notes
Plan Review Notes For Permit 01050154
Permit Number 01050154
Review Stop FIRE
Sequence Number 2
Notes
Date Text
2001-06-12 00:00:001) A RECENT SURVEY OF THE BASEMENT
 STAIRWAY INDICATED SEVERAL CODE
 VIOLATIONS. THEY INCLUDE NO HANDRAILS,
 CONDUIT AND A FUSE PANEL, EXISTING
 ELECTRICAL CONDUITS, NO EMERGENCY
 LIGHTING, HOLES IN WALLS, OPEN
 ELECTRICAL BOXES, AND OTHER VIOLATIONS.
 HOW DOES PROTECTING THE EXISTING CONDUIT
 WITH DRYWALL INTERFERE WITH INSTALLATION
 OF HANDRAILS AND MEET THE MINIMUM
 DIMENSIONS OF AT 36" WIDE STAIRS FOR
 OCCUPANT LOADS OF LESS THAN 50 PERSONS.
 2) PLEASE PROVIDE DIMENSIONS OF NEW
 SHAFT.
 3) IF THE NEW SHAFT IS APPROVED BY
 THE BUILDINGS PLAN REVIEWER, IT SHALL
 NOT INTERFERE WITH MINIMUM CODE
 REQUIREMENTS FOR THE BASEMENT STAIRWAY.