Plan Review Notes For Permit 01050105
Permit Number 01050105
Review Stop ENG
Sequence Number 1
Notes
Date Text
2001-05-15 00:00:00FAILED:
 1. PLEASE PROVIDE STORM WATER
 CALCULATION FOR OUR REVIEW IF YOU HAVE
 NOT SUBMITTED TO JOSE DEL RIO, STORM
 WATER ENGINEER AT 1000 45TH STREET WEST
 PALM BEACH, FL 33407.PLEASE SEE
 ATTACHED
 2. ANY WORK WITHIN PUBLIC R.O.W REQUIRES
 A SEPARATE PERMIT THROUGH OFFICE OF CITY
 ENGINEER AT 1000 45TH STREET WEST PALM
 BEACH FL 33407.
 3. ANY NEW CONNECTION TO CITY UTILITY
 SERVICES REQUIRES A SEPARATE PERMIT
 THROUGH PUBLIC UTILITIES ENGINEERING
 SERVICES DEPARTMENT AT 1000 45TH STREET
 WEST PALM BEACH, FL 33407.
 4. PLEASE CLEARLY SHOW THE APPROACH
 DRIVEWAY TO THE FACILITY, ALSO SHOW TYPE
 , SIZE, SIDEWALK CURB / GUTTER, ETC.
 SEE ATTACHED
 5. PLEASE SHOW UNDERGROUND UTILITY WORKS
 6. SHOW LOCATION OF BACKFLOW PREVENTERS
 AND LOCATION OF CONNECTION TO CITY
 SERVICES.
 7. PROVIDE POLLUTION PREVENTION PLANS,
 PALNS SHOULD BE INSTALLED IN FIELD PRIOR
 TO ANY CONSTRUCTION WORK.IT SHOULD BE
 KEPT ON CONSTROCTION SITE DURING THE
 CONSTRUCTION.
 8. A CLEAN-OUT WILL NEED TO BE INSTALLED
 IN THE SANITARY SEWER LATERAL, ON
 PROPERTY, AT THE BACK OF THE SIDEWALK IF
 NOT ALREADY INSTALLED.
 9. IS THERE ANY IRRIGATION SYS. BEING
 PLANED? IF SO A SEPARATE BACKFLOW
 PREVENTER SHOULD BE INSTALLED IN THIS
 LINE.
 10. PLEASE SPECIFIED THE THE TYPE OF
 PAVEMENTS, DETAILS, THICKNESS, ETC..
 11. PLEASE PROVIDE PERVIOUS AND IMPERVIO
 US CALCULATION FOR ENTIRE SITE.PLEASE
 NOTE THAT THE TOTAL MUST ADD UP TO 100%
 OF TOTAL SITE AREA.PROVIDE THIS
 INFORMATION ON A 8 1/2 X 11 SHEET,
 SIGNED AND SEALED BY THE DESIGN ENGINEER
 PLEASE INCLUDE PROPERTY CONTROL NUMBER,
 NAME AND ADDRESS.THIS DATA WILL BE
 USED TO COMPUTE NEW STORM WATER CHARGES
 THAT MY APPLY.
 IF ANY QUESTION PLEASE CONTACT 659-8096
 EXT. 8492