| Date |
Text |
| 2001-06-01 00:00:00 | CHECKLIST: |
| | 1-DESIGNER IS NOT A REGISTERED ARCHITECT |
| | OR ENGINEER. DESIGNER SHALL USE THE |
| | PRESCRIPTIVE STANDARD SSTD 10-97 TO |
| | DESIGN THIS STRUCTURE. SEC. 104.2.3 |
| | OF CITY AMENDMENTS TO SBC 1997. |
| | -DESIGNER TO USE SSTD 10-97 CHAPTER TWO |
| | TO DESIGN: |
| | -FOOTINGS AND FOUNDATIONS. |
| | -WALL SYSTEMS. SHOW SHEARWALLS |
| | LOCATIONS AND REINFORCEMENT. |
| | -SHOW REINFORCEMENT AT CORNERS. |
| | -SHOW REINFORCEMENT AT OPENINGS. |
| | -SHOW RAKE BEAM SIZE & REINFORCEMENT. |
| | 2-PROVIDE SOIL TEST REPORT. |
| | SECTION 1804.2.2 CITY AMENDMENTS. |
| | 3-PROVIDE COMPLETE ROOF FRAMING PLAN AND |
| | ANCHOR SCHEDULE. |
| | SECTION 104.2.2 CITY AMENDMENTS. |
| | 4-PROVIDE ENERGY CALCULATIONS. |
| | 5-PROVIDE NOTICE OF COMMENCEMENT. |
| | 6-PROVIDE COMPLETE INFORMATION FOR |
| | STORM SHUTTERS: |
| | -KEY PLAND AND COMPLETE INSTALLATION |
| | SCHEDULE (SEE ATTACHED CITY SAMPLE). |
| | -PROVIDE STORM PANELS PRODUCT APPROVAL |
| | AND CIRCLE ON DRAWINGS SPECIFIC |
| | MOUNTING CONDITIONS AND ANCHORS TO BE |
| | USED ACCORDING TO THE MEAN ROOF HEIGHT |
| | DESIGN PRESSURES, EDGE DISTANCE, PANEL |
| | SPAN, CONNECTION TYPE AND STRUCTURE TO |
| | BE ATTACHED TO (CONCRETE BLOCK). |
| | 7-PROVIDE ATTIC ACCESS. SECTION 2309.6 |
| | SBC 1997. |
| | 8-SPECIFY UPLIFT ANCHOR FOR GABLE END |
| | ROOF TRUSS. SEC 104.2.2 CITY AMENDMENT |
| | 9-ZONING ONLY ALLOWS ONE KITCHEN PER |
| | RESIDENCE. PROVIDE DRAWINGS SHOWING |
| | WHAT IS GOING TO BE DONE ON EXISTING |
| | KITCHEN. |
| | 10-SEE COMMENTS BY THE OTHER TRADES AND |
| | RETURN REVIEWED SET AFTER CORRECTIONS |
| | ARE DONE TO THE ORIGINAL DRAWINGS IN |
| | ORDER TO EXPEDITE THE REVIEW PROCESS. |
| | 11-PROVIDE CURRENT PRODUCT APPROVAL FOR: |
| | -EXTERIOR DOOR. (SUBMITTED ONE EXPIRED) |
| | 12-DESIGNER CAN NOT FILL AND SIGN THE |
| | DESIGN CERTIFICATION FOR BUILDING CODE |
| | COMPLIANCE FORM. THIS IS TO BE FILLED |
| | AND SEALED BY A REGISTER ARCHITECT OR |
| | ENGINEER ONLY. |
| | 13-VALUE DECLARED FOR CONSTRUCTION IS |
| | TOO LOW. OWES $928.97 FOR UPDATED |
| | VALUE AND RADON FEES. |
| | -IF YOU HAVE ANY QUESTIONS, PLEASE CALL |
| | JULIO GOMEZ AT 659-8096 EXT. 8232. |